York / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 32

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,000927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU36B5XDS2+TXV+ furnace: Y81E080B12LMPS1AHRI reference: 21850300218.008.50248002.00EPA 4639645 →
CTU36B5XDS2+TXV+ furnace: Y81E080B12SMPS1AHRI reference: 21850299818.008.50248002.00EPA 4639646 →
CTF36B5CDS2+ furnace: Y81E080B12LMPS1AHRI reference: 21850299618.008.50248002.00EPA 4639647 →
CTF36B5CDS2+ furnace: Y81E080B12SMPS1AHRI reference: 21850299318.008.50248002.00EPA 4639648 →
CTF36B5ADS2+ furnace: Y81E080B12LMPS1AHRI reference: 21850299018.008.50248002.00EPA 4639649 →
CTF36B5ADS2+ furnace: Y81E080B12SMPS1AHRI reference: 21850298718.008.50248002.00EPA 4639650 →
CTU36B5XDS2+TXV+ furnace: Y92E080B12SMPS1AHRI reference: 21850297518.008.50240002.00EPA 4639654 →
CTF36B5CDS2+ furnace: Y92E080B12SMPS1AHRI reference: 21850297218.008.50240002.00EPA 4639655 →
CTF36B5ADS2+ furnace: Y92E080B12SMPS1AHRI reference: 21850296818.008.50240002.00EPA 4639656 →
CTF30A5ADS2+ furnace: Y81E040A12LMPS1AHRI reference: 21850296218.008.50248002.00EPA 4639658 →
CTF30A5ADS2+ furnace: Y81E040A12SMPS1AHRI reference: 21850295918.008.50248002.00EPA 4639659 →
CTF30A5ADS2+ furnace: TL8E060A12UH11AHRI reference: 21850295618.008.00254002.00EPA 4639660 →
CTM36B5CDS2+ furnace: Y82V080B12SMPC1AHRI reference: 21850438118.009.00228002.00EPA 4641086 →
CTM36B5ADS2+ furnace: Y82V080B12SMPC1AHRI reference: 21850437818.009.00228002.00EPA 4641087 →
CTM36B5CDS2+ furnace: Y82E080B12LMPS1AHRI reference: 21850437518.008.50240002.00EPA 4641088 →
CTM36B5ADS2+ furnace: Y82E080B12LMPS1AHRI reference: 21850437218.008.50240002.00EPA 4641089 →
CTM36B5CDS2+ furnace: Y92E080B12SMPS1AHRI reference: 21850436818.008.50240002.00EPA 4641090 →
CTM36B5ADS2+ furnace: Y92E080B12SMPS1AHRI reference: 21850436418.008.50240002.00EPA 4641091 →
CTM36B5CDS2+ furnace: Y92E060B12SMPS1AHRI reference: 21850436118.008.50242002.00EPA 4641092 →
CTM36B5ADS2+ furnace: Y92E060B12SMPS1AHRI reference: 21850435818.008.50242002.00EPA 4641093 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →