York / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 15

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,000927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM48C5CFS2+ furnace: Y82V100C16SMPC1AHRI reference: 21850363719.009.00230002.00EPA 4641315 →
CTM48C5CFS2+ furnace: Y82V080C16SMPC1AHRI reference: 21850363319.009.00230002.00EPA 4641316 →
CTM48C5CFS2+ furnace: Y81E120C20LMPS1AHRI reference: 21850362319.009.00254002.00EPA 4641318 →
CTM48C5CFS2+ furnace: Y81E120C20SMPS1AHRI reference: 21850362119.009.00254002.00EPA 4641319 →
CTM48C5CFS2+ furnace: Y91E080C20SMPS1AHRI reference: 21850361419.009.00256002.00EPA 4641320 →
CTM48C5CFS2+ furnace: Y81E100C16LMPS1AHRI reference: 21850361019.009.00252002.00EPA 4641321 →
CTM48C5CFS2+ furnace: Y81E100C16SMPS1AHRI reference: 21850360719.009.00252002.00EPA 4641322 →
CTM48C5CFS2+ furnace: Y81E120C16LMPS1AHRI reference: 21850360219.009.00252002.00EPA 4641323 →
CTM48C5CFS2+ furnace: Y81E120C16SMPS1AHRI reference: 21850359919.009.00252002.00EPA 4641324 →
CTM48C5CFS2+ furnace: YP9C100C20MP13AHRI reference: 21850359019.009.00258002.00EPA 4641326 →
CTM48C5CFS2+ furnace: TP9C100C20MP13AHRI reference: 21850358719.009.00258002.00EPA 4641327 →
CTM48C5CFS2+ furnace: TM9V100C20MP12AHRI reference: 21850358419.009.00258002.00EPA 4641328 →
CTM48C5CFS2+ furnace: TM8V080C16MP12AHRI reference: 21850357819.009.00252002.00EPA 4641329 →
CTM48C5CFS2+ furnace: TM8V100C16MP12AHRI reference: 21850357519.009.00252002.00EPA 4641330 →
CTM48C5CFS2+ furnace: Y91E080C16SMPS1AHRI reference: 21850356619.009.00258002.00EPA 4641331 →
CTM48C5CFS2+ furnace: YP9C100C16MP13AHRI reference: 21850356319.009.00252002.00EPA 4641332 →
CTM48C5CFS2+ furnace: TP9C100C16MP13AHRI reference: 21850356019.009.00252002.00EPA 4641333 →
CTM48C5CFS2+ furnace: TM9V100C16MP12AHRI reference: 21850355719.009.00252002.00EPA 4641334 →
CTM48C5CFS2+ furnace: Y81E080C20LMPS1AHRI reference: 21850355119.009.00254002.00EPA 4641335 →
CTM48C5CFS2+ furnace: Y81E080C20SMPS1AHRI reference: 21850354719.009.00254002.00EPA 4641336 →