HH836E2S11
LX SERIES · source records, page 13
927 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 927 / 927 |
| EER2 · BTU/Wh | 10–12 | 927 / 927 |
| HSPF2 · BTU/Wh | 8–9.5 | 927 / 927 |
| Cooling capacity · BTU/h | 31,600–35,000 | 927 / 927 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,000 | 927 / 927 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 927 / 927 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 927 / 927 |
| COP at 5°F / −15°C | 2–2.1 | 927 / 927 |
| Equipment / loop type | HP - Split System | 927 / 927 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 927 / 927 |
| Compressor staging | Continuously variable | 927 / 927 |
| Connected capability | No | 927 / 927 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF48C5CFS2+ furnace: Y81E080C16LMPS1AHRI reference: 218504060 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4641184 → |
CTF48C5CFS2+ furnace: Y81E080C16SMPS1AHRI reference: 218504058 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4641185 → |
CTU48C5XFS2+TXV+ furnace: Y81E100C16LMPS1AHRI reference: 218504013 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4641198 → |
CTU48C5XFS2+TXV+ furnace: Y81E100C16SMPS1AHRI reference: 218504009 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4641199 → |
CTF48C5CFS2+ furnace: Y81E100C16LMPS1AHRI reference: 218504007 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4641200 → |
CTF48C5CFS2+ furnace: Y81E100C16SMPS1AHRI reference: 218504004 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4641201 → |
CTU48C5XFS2+TXV+ furnace: Y81E120C20LMPS1AHRI reference: 218503973 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4641208 → |
CTU48C5XFS2+TXV+ furnace: Y81E120C20SMPS1AHRI reference: 218503969 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4641209 → |
CTF48C5CFS2+ furnace: Y81E120C20LMPS1AHRI reference: 218503967 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4641210 → |
CTF48C5CFS2+ furnace: Y81E120C20SMPS1AHRI reference: 218503963 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4641211 → |
CTU48C5XFS2+TXV+ furnace: Y92E080C16SMPS1AHRI reference: 218503948 | 19.00 | 9.50 | 24200 | 2.00 | EPA 4641214 → |
CTF48C5CFS2+ furnace: Y92E080C16SMPS1AHRI reference: 218503945 | 19.00 | 9.50 | 24200 | 2.00 | EPA 4641215 → |
CTU48C5XFS2+TXV+ furnace: Y92E100C16SMPS1AHRI reference: 218503941 | 19.00 | 9.50 | 23800 | 2.00 | EPA 4641216 → |
CTF48C5CFS2+ furnace: Y92E100C16SMPS1AHRI reference: 218503938 | 19.00 | 9.50 | 23800 | 2.00 | EPA 4641217 → |
CTF36C5CDS2+JMC16C2SN1AHRI reference: 218503883 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4641230 → |
CTF36C5ADS2+JMC16C2SN1AHRI reference: 218503881 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4641231 → |
CTF36C5CDS2+JMVT17CC2N1AHRI reference: 218503878 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4641232 → |
CTF36C5ADS2+JMVT17CC2N1AHRI reference: 218503876 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4641233 → |
CTF36C5CDS2+JMVT16CC2N1AHRI reference: 218503873 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4641234 → |
CTF36C5ADS2+JMVT16CC2N1AHRI reference: 218503870 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4641235 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →