York / AIR-SOURCE HEAT PUMP

HH824E2S12

LX SERIES · source records, page 4

264 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 264 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18264 / 264
EER2 · BTU/Wh11–12264 / 264
HSPF2 · BTU/Wh8.1–8.5264 / 264
Cooling capacity · BTU/h22,400–24,000264 / 264
Heating capacity at 47°F / 8.3°C · BTU/h22,000–24,000264 / 264
Heating capacity at 17°F / −8.3°C · BTU/h20,600–22,800264 / 264
Heating capacity at 5°F / −15°C · BTU/h17,200–18,700264 / 264
COP at 5°F / −15°C2.22–2.46264 / 264
Equipment / loop typeHP - Split System264 / 264
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)264 / 264
Compressor stagingTwo-stage264 / 264
Connected capabilityNo264 / 264

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30B5ACS2+ furnace: Y91E080B12SMPS1Cold climate designationAHRI reference: 21864168417.008.50182002.30EPA 4664825
CTU30B5XCS2+TXV+ furnace: Y81E080B12LMPS1Cold climate designationAHRI reference: 21864168317.008.50181002.32EPA 4664826
CTU30B5XCS2+TXV+ furnace: Y81E080B12SMPS1Cold climate designationAHRI reference: 21864168217.008.50181002.32EPA 4664827
CTF30B5ACS2+ furnace: Y81E080B12LMPS1Cold climate designationAHRI reference: 21864168117.008.50181002.32EPA 4664828
CTF30B5ACS2+ furnace: Y81E080B12SMPS1Cold climate designationAHRI reference: 21864168017.008.50181002.32EPA 4664829
CTM30B5ACS2+ furnace: Y81E080B12LMPS1Cold climate designationAHRI reference: 21864167917.008.50181002.30EPA 4664830
CTM30B5ACS2+ furnace: Y81E080B12SMPS1Cold climate designationAHRI reference: 21864167817.008.50181002.30EPA 4664831
CTM30B5ACS2+JME12B2SN2Cold climate designationAHRI reference: 21864167717.008.50175002.26EPA 4664832
CTU30B5XCS2+JME08B2SN2+TXVAHRI reference: 21864167417.008.10172002.24EPA 4664835
CTF30B5ACS2+JME08B2SN2AHRI reference: 21864167317.008.10172002.24EPA 4664836
CTM30B5ACS2+ furnace: Y82E080B12LMPS1Cold climate designationAHRI reference: 21864167217.008.50181002.30EPA 4664837
CTM30B5ACS2+JMC12B2SN1Cold climate designationAHRI reference: 21864167017.008.50180002.32EPA 4664839
CTU30B5XCS2+TXV+ furnace: Y92E060B12SMPS1Cold climate designationAHRI reference: 21864166717.008.50184002.30EPA 4664842
CTF30B5ACS2+ furnace: Y92E060B12SMPS1Cold climate designationAHRI reference: 21864166617.008.50184002.30EPA 4664843
CTM30B5ACS2+JME08B2SN2AHRI reference: 21864166417.008.10172002.22EPA 4664845
CTU36B5XDS2+TXV+ furnace: YP9C080B12MP13Cold climate designationAHRI reference: 21868835617.008.50181002.38EPA 4678883
CTU36B5XDS2+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21868835517.008.50181002.38EPA 4678884
CTU36B5XDS2+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21868835417.008.50181002.38EPA 4678885
CTF36B5ADS2+ furnace: YP9C080B12MP13Cold climate designationAHRI reference: 21868835317.008.50181002.38EPA 4678886
CTF36B5ADS2+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21868835217.008.50181002.38EPA 4678887

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.