HH824E2S11
LX SERIES · source records, page 9
339 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH824E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 339 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 339 / 339 |
| EER2 · BTU/Wh | 11–12 | 339 / 339 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 339 / 339 |
| Cooling capacity · BTU/h | 23,000–24,000 | 339 / 339 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000–24,000 | 339 / 339 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,100–18,900 | 339 / 339 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–19,400 | 339 / 339 |
| COP at 5°F / −15°C | 2–2.1 | 339 / 339 |
| Equipment / loop type | HP - Split System | 339 / 339 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 339 / 339 |
| Compressor staging | Continuously variable | 339 / 339 |
| Connected capability | No | 339 / 339 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36B5ADS2+ furnace: Y81E060A12LMPS1AHRI reference: 218502670 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4639753 → |
CTM36B5ADS2+ furnace: Y81E060A12SMPS1AHRI reference: 218502666 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4639754 → |
CTM36B5ADS2+ furnace: Y91E080B12SMPS1AHRI reference: 218502664 | 18.00 | 9.50 | 18600 | 2.00 | EPA 4639755 → |
CTM36B5ADS2+ furnace: Y81E100B12LMPS1AHRI reference: 218502661 | 18.00 | 9.50 | 18800 | 2.00 | EPA 4639756 → |
CTM36B5ADS2+ furnace: Y81E100B12SMPS1AHRI reference: 218502659 | 18.00 | 9.50 | 18800 | 2.00 | EPA 4639757 → |
CTM36B5ADS2+ furnace: YP9C080B12MP13AHRI reference: 218502656 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4639758 → |
CTM36B5ADS2+ furnace: TP9C080B12MP13AHRI reference: 218502653 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4639759 → |
CTM36B5ADS2+ furnace: TM9V080B12MP12AHRI reference: 218502650 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4639760 → |
CTM36B5ADS2+JMC12B2SN1AHRI reference: 218502645 | 18.00 | 9.50 | 18600 | 2.00 | EPA 4639762 → |
CTM36B5ADS2+JMVT12BC2N1AHRI reference: 218502642 | 18.00 | 9.50 | 18600 | 2.00 | EPA 4639763 → |
CTM36B5ADS2+ furnace: TL9E060B12UH11AHRI reference: 218502640 | 18.00 | 9.00 | 18900 | 2.00 | EPA 4639764 → |
CTM36B5ADS2+ furnace: Y92E060B12SMPS1AHRI reference: 218502635 | 18.00 | 9.50 | 18400 | 2.00 | EPA 4639766 → |
CTM36B5ADS2+ furnace: Y92E080B12SMPS1AHRI reference: 218502632 | 18.00 | 9.00 | 17400 | 2.00 | EPA 4639767 → |
CTM30B5ACS2+JMC12B2SN1AHRI reference: 218502629 | 18.00 | 9.50 | 19000 | 2.00 | EPA 4639768 → |
CTM30B5ACS2+JMVT12BC2N1AHRI reference: 218502625 | 18.00 | 9.50 | 19000 | 2.00 | EPA 4639769 → |
CTM30B5ACS2+ furnace: Y81E080B12LMPS1AHRI reference: 218502614 | 18.00 | 9.50 | 19100 | 2.00 | EPA 4639773 → |
CTM30B5ACS2+ furnace: Y81E080B12SMPS1AHRI reference: 218502611 | 18.00 | 9.50 | 19100 | 2.00 | EPA 4639774 → |
CTM30B5ACS2+ furnace: Y91E080B12SMPS1AHRI reference: 218502592 | 18.00 | 9.50 | 19100 | 2.00 | EPA 4639781 → |
CTM30B5ACS2+ furnace: Y82E080B12LMPS1AHRI reference: 218502590 | 18.00 | 9.50 | 18400 | 2.00 | EPA 4639782 → |
CTM30B5ACS2+ furnace: Y81E100B12LMPS1AHRI reference: 218502587 | 18.00 | 9.50 | 19400 | 2.00 | EPA 4639783 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →