York / AIR-SOURCE HEAT PUMP

HH824E2S11

LX SERIES · source records, page 16

339 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity23,000–24,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 339 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19339 / 339
EER2 · BTU/Wh11–12339 / 339
HSPF2 · BTU/Wh8.5–9.5339 / 339
Cooling capacity · BTU/h23,000–24,000339 / 339
Heating capacity at 47°F / 8.3°C · BTU/h23,000–24,000339 / 339
Heating capacity at 17°F / −8.3°C · BTU/h17,100–18,900339 / 339
Heating capacity at 5°F / −15°C · BTU/h17,000–19,400339 / 339
COP at 5°F / −15°C2–2.1339 / 339
Equipment / loop typeHP - Split System339 / 339
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)339 / 339
Compressor stagingContinuously variable339 / 339
Connected capabilityNo339 / 339

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM30B5ACS2+ furnace: TM8V080B12MP12AHRI reference: 21850262317.009.50179002.00EPA 4639770 →
CTM30B5ACS2+ furnace: Y91E060B12SMPS1AHRI reference: 21850262017.009.50192002.00EPA 4639771 →
CTM30B5ACS2+ furnace: TL9E060B12UH11AHRI reference: 21850261717.009.50183002.00EPA 4639772 →
CTM30B5ACS2+ furnace: YP9C080B12MP13AHRI reference: 21850260817.009.50178002.00EPA 4639775 →
CTM30B5ACS2+ furnace: TP9C080B12MP13AHRI reference: 21850260617.009.50178002.00EPA 4639776 →
CTM30B5ACS2+ furnace: TM9V080B12MP12AHRI reference: 21850260317.009.50178002.00EPA 4639777 →
CTM30B5ACS2+ furnace: YP9C060B12MP13AHRI reference: 21850260017.009.50180002.00EPA 4639778 →
CTM30B5ACS2+ furnace: TP9C060B12MP13AHRI reference: 21850259817.009.50180002.00EPA 4639779 →
CTM30B5ACS2+ furnace: TM9V060B12MP12AHRI reference: 21850259517.009.50180002.00EPA 4639780 →
CTU36B5XDS2+TXV+ furnace: Y91E060B12SMPS1AHRI reference: 21850254617.009.50187002.00EPA 4639798 →
CTF36B5ADS2+ furnace: Y91E060B12SMPS1AHRI reference: 21850254317.009.50187002.00EPA 4639799 →
CTU30B5XCS2+TXV+ furnace: YP9C080B12MP13AHRI reference: 21850245117.009.50182002.00EPA 4639832 →
CTU30B5XCS2+TXV+ furnace: TP9C080B12MP13AHRI reference: 21850244817.009.50182002.00EPA 4639833 →
CTU30B5XCS2+TXV+ furnace: TM9V080B12MP12AHRI reference: 21850244517.009.50182002.00EPA 4639834 →
CTF30B5ACS2+ furnace: YP9C080B12MP13AHRI reference: 21850244217.009.50182002.00EPA 4639835 →
CTF30B5ACS2+ furnace: TP9C080B12MP13AHRI reference: 21850243917.009.50182002.00EPA 4639836 →
CTF30B5ACS2+ furnace: TM9V080B12MP12AHRI reference: 21850243717.009.50182002.00EPA 4639837 →
CTU30B5XCS2+TXV+ furnace: TM8V080B12MP12AHRI reference: 21850242817.009.50179002.00EPA 4639840 →
CTF30B5ACS2+ furnace: TM8V080B12MP12AHRI reference: 21850242517.009.50179002.00EPA 4639841 →
CTU30B5XCS2+TXV+ furnace: TL9E060B12UH11AHRI reference: 21850242217.009.50184002.00EPA 4639842 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →