WEATHERMAKER / AIR-SOURCE HEAT PUMP

PH8TAN560**AB*

2-STAGE 18 SEER HP · source records, page 3

49 published source records · source checked Sep 21, 2026

SEER2 range16–17.5BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN560**AB*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 49 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–17.549 / 49
EER2 · BTU/Wh11.7–1349 / 49
HSPF2 · BTU/Wh8–8.549 / 49
Cooling capacity · BTU/h54,000–58,00049 / 49
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,50049 / 49
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50049 / 49
Heating capacity at 5°F / −15°C · BTU/h29,600–31,80049 / 49
COP at 5°F / −15°C2.12–2.3449 / 49
Equipment / loop typeHP - Split System49 / 49
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)49 / 49
Compressor stagingTwo-stage49 / 49
Connected capabilityNo49 / 49

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21875510116.008.10306002.22EPA 4705842
CVAMA6124XMA*+ furnace: PG80VTLB66135D**AHRI reference: 21875509516.008.50314002.34EPA 4705843
CVAMA6124XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21875509316.008.50318002.32EPA 4705844
CVAMA6124XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21875509116.008.50316002.32EPA 4705845
CVAMA6021XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21875508316.008.10302002.22EPA 4705846
CVAMA6021XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21875508016.008.10300002.24EPA 4705847
CVAMA6021XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21875507816.008.10304002.24EPA 4705848
CVAMA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21875507716.008.10298002.24EPA 4705849
CVAMA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21875507616.008.10300002.22EPA 4705850

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →