WEATHERMAKER / AIR-SOURCE HEAT PUMP

PH8TAN560**AA*

2-STAGE 18 SEER HP · source records, page 2

49 published source records · source checked Sep 21, 2026

SEER2 range16–17.5BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN560**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 49 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–17.549 / 49
EER2 · BTU/Wh11.7–1349 / 49
HSPF2 · BTU/Wh8–8.549 / 49
Cooling capacity · BTU/h54,000–58,00049 / 49
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,50049 / 49
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50049 / 49
Heating capacity at 5°F / −15°C · BTU/h29,600–31,80049 / 49
COP at 5°F / −15°C2.12–2.3449 / 49
Equipment / loop typeHP - Split System49 / 49
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)49 / 49
Compressor stagingTwo-stage49 / 49
Connected capabilityNo49 / 49

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA6021XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562610716.008.10302002.22EPA 3950309
CVAMA6124XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562654316.008.50316002.32EPA 3950369
CVAVA6121XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562778216.008.10306002.22EPA 3950549
CVAVA6121XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562780116.008.10310002.20EPA 3950594
CVAVA6121XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562786216.008.10310002.22EPA 3950659
CVAVA6121XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562801116.008.10314002.18EPA 3950689
CVAVA6124XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562817416.008.50316002.34EPA 3950747
CAA**6024AM*+ furnace: PG80VTLB66110C**AHRI reference: 21562920216.008.00298002.30EPA 3950905
CAA**6024AM*+ furnace: PG80VTLB66135D**AHRI reference: 21562922016.008.00296002.30EPA 3950921
CAA**6024AM*+ furnace: PG80MSUA60100C**AHRI reference: 21562911116.008.00296002.30EPA 3951026
CAA**6024AM*+ furnace: PG80VTLB60090C**AHRI reference: 21562918616.008.00298002.25EPA 3951085
CAA**6121AM*+ furnace: PG95MSUA60080C**AHRI reference: 21562985616.008.00302002.25EPA 3951100
CAA**6121AM*+ furnace: PG95MSUA60100C**AHRI reference: 21562987516.008.00302002.30EPA 3951121
CAA**6024AM*+ furnace: PG95MSUA60080C**AHRI reference: 21562935116.008.00300002.25EPA 3951234
CAA**6121AM*+ furnace: PG96VTAB60080C**AHRI reference: 21562993616.008.00304002.25EPA 3951267
CAA**6121AM*+ furnace: PG96VTAB60100C**AHRI reference: 21562995416.008.00302002.30EPA 3951293
CAA**6024AM*+ furnace: PG95MSUA60100C**AHRI reference: 21562937016.008.00300002.25EPA 3951311
CAA**6024AM*+ furnace: PG96VTAB60080C**AHRI reference: 21562944516.008.00300002.25EPA 3951369
CAA**6024AM*+ furnace: PG96VTAB60100C**AHRI reference: 21562946316.008.00298002.25EPA 3951460
CAA**6024AM*+ furnace: PG96VTAB66120D**AHRI reference: 21562949616.008.00300002.25EPA 3951493

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →