PH8TAN548**AB*
2-STAGE 18 SEER HP
150 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH8TAN548**AB*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 150 / 150 |
| EER2 · BTU/Wh | 11.7–13.5 | 150 / 150 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 150 / 150 |
| Cooling capacity · BTU/h | 46,000–50,500 | 150 / 150 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 150 / 150 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,400 | 150 / 150 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 150 / 150 |
| COP at 5°F / −15°C | 2.1–2.32 | 150 / 150 |
| Equipment / loop type | HP - Split System | 150 / 150 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 150 / 150 |
| Compressor staging | Two-stage | 150 / 150 |
| Connected capability | No | 150 / 150 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
PF5TNBD60L*AHRI reference: 218754767 | 18.00 | 8.10 | 24600 | 2.32 | EPA 4705955 → |
QFVA5D6021X*AHRI reference: 218755724 | 18.00 | 8.50 | 25800 | 2.32 | EPA 4706236 → |
CVAVA6124XMA*+ furnace: PG80VTLB66135D**AHRI reference: 218755070 | 17.50 | 8.50 | 25000 | 2.26 | EPA 4705856 → |
CVAVA6124XMA*+ furnace: PG80VTLB66110C**AHRI reference: 218755069 | 17.50 | 8.50 | 24800 | 2.28 | EPA 4705857 → |
CVAVA6121XMA*+ furnace: PG80VTLB66110C**AHRI reference: 218755062 | 17.50 | 8.10 | 24600 | 2.14 | EPA 4705864 → |
CVAVA6121XMA*+ furnace: PG80MSUA60100C**AHRI reference: 218755060 | 17.50 | 8.50 | 25000 | 2.26 | EPA 4705866 → |
CVAVA6121XMA*+ furnace: PG80MSUA60080C**AHRI reference: 218755059 | 17.50 | 8.50 | 24400 | 2.30 | EPA 4705867 → |
CVAVA6121XMA*+ furnace: PG80MSUA48060B**AHRI reference: 218755058 | 17.50 | 8.10 | 25000 | 2.12 | EPA 4705868 → |
CVAVA4924XMA*+ furnace: PG80MSUA60080C**AHRI reference: 218755044 | 17.50 | 8.10 | 24600 | 2.14 | EPA 4705882 → |
CVAMA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 218755028 | 17.50 | 8.10 | 24400 | 2.14 | EPA 4705898 → |
CVAMA4921XMA*+ furnace: PG80MSUA60080C**AHRI reference: 218755019 | 17.50 | 8.10 | 24400 | 2.14 | EPA 4705907 → |
QFVA5D4821X*AHRI reference: 218755723 | 17.50 | 8.10 | 25400 | 2.18 | EPA 4706237 → |
PF5TNXC48L*AHRI reference: 218755134 | 17.00 | 8.10 | 24600 | 2.28 | EPA 4705830 → |
CVAVA6021XMA*+ furnace: PG80VTLB60090C**AHRI reference: 218755132 | 17.00 | 8.10 | 24600 | 2.10 | EPA 4705832 → |
CVAVA6124XMA*+ furnace: PG96VTAB60100C**AHRI reference: 218755074 | 17.00 | 8.10 | 25200 | 2.12 | EPA 4705852 → |
CVAVA6124XMA*+ furnace: PG96VTAB60080C**AHRI reference: 218755073 | 17.00 | 8.50 | 25600 | 2.10 | EPA 4705853 → |
CVAVA6124XMA*+ furnace: PG95MSUA60100C**AHRI reference: 218755072 | 17.00 | 8.10 | 25200 | 2.12 | EPA 4705854 → |
CVAVA6124XMA*+ furnace: PG80VTLB60090C**AHRI reference: 218755068 | 17.00 | 8.50 | 25000 | 2.26 | EPA 4705858 → |
CVAVA6124XMA*+ furnace: PG80MSUA60100C**AHRI reference: 218755067 | 17.00 | 8.50 | 25000 | 2.26 | EPA 4705859 → |
CVAVA6121XMA*+ furnace: PG96VTAB60100C**AHRI reference: 218755066 | 17.00 | 8.10 | 25000 | 2.12 | EPA 4705860 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →