WEATHERMAKER / AIR-SOURCE HEAT PUMP

PH8TAN536**AB*

2-STAGE 18 SEER HP · source records, page 2

104 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN536**AB*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 104 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17104 / 104
EER2 · BTU/Wh11.7–13104 / 104
HSPF2 · BTU/Wh7.8–8.5104 / 104
Cooling capacity · BTU/h33,800–38,000104 / 104
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000104 / 104
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200104 / 104
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600104 / 104
COP at 5°F / −15°C1.78–2.48104 / 104
Equipment / loop typeHP - Split System104 / 104
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)104 / 104
Compressor stagingTwo-stage104 / 104
Connected capabilityNo104 / 104

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA4821XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21875499715.507.80177001.78EPA 4705920
CVAVA3817XMA*+ furnace: PG96VTAB48080B**AHRI reference: 21875497715.507.80179001.80EPA 4705922
CVAVA3817XMA*+ furnace: PG95MSUA48060B**AHRI reference: 21875497515.507.80178001.78EPA 4705924
CVAVA3817XMA*+ furnace: PG80VTLB48070B**AHRI reference: 21875497315.507.80177001.80EPA 4705926
CVAVA3721XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21875496415.507.80177001.80EPA 4705931
CVAVA3721XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21875496115.507.80177001.78EPA 4705932
CVAMA4921XMA*+ furnace: PG80VTLB48090B**AHRI reference: 21875493715.507.80180001.78EPA 4705935
CVAMA4821XMA*+ furnace: PG96VTAB60100C**AHRI reference: 21875493415.507.80178001.78EPA 4705938
CVAMA4821XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21875492415.507.80177001.78EPA 4705942
CAA**4321AM*+ furnace: PG97VTAA60100C**AHRI reference: 21875570415.508.00192002.26EPA 4706256
CAA**3721AM*+ furnace: PG97VTAA60100C**AHRI reference: 21875570115.508.00193002.26EPA 4706257
CSAH*4212AM*+ furnace: PG80MSUA60080C**AHRI reference: 21875535215.508.10190002.26EPA 4706441
CAA**4821AM*+ furnace: PG96VTAB60100C**AHRI reference: 21875533415.508.10191002.26EPA 4706444
CAA**4821AM*+ furnace: PG95MSUA60100C**AHRI reference: 21875533015.508.10191002.26EPA 4706446
CAA**4821AM*+ furnace: PG80VTLB66110C**AHRI reference: 21875532615.508.10191002.26EPA 4706448
CAA**4821AM*+ furnace: PG80VTLB60090C**AHRI reference: 21875532515.508.10192002.26EPA 4706449
CAA**4821AM*+ furnace: PG80MSUA60100C**AHRI reference: 21875532215.508.10193002.22EPA 4706452
CAA**4821AM*+ furnace: PG80MSUA48060B**AHRI reference: 21875532015.508.10190002.28EPA 4706454
CAA**4821AM*+ furnace: PG80MSUA36040B**AHRI reference: 21875531915.508.10192002.24EPA 4706455
CAA**4321AM*+ furnace: PG96VTAB60100C**AHRI reference: 21875531815.508.10192002.26EPA 4706456

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.