SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN524**AB*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 187 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5187 / 187
EER2 · BTU/Wh11.7–14187 / 187
HSPF2 · BTU/Wh7.8–8.5187 / 187
Cooling capacity · BTU/h22,200–25,000187 / 187
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,200187 / 187
Heating capacity at 17°F / −8.3°C · BTU/h14,100–14,900187 / 187
Heating capacity at 5°F / −15°C · BTU/h10,700–11,400187 / 187
COP at 5°F / −15°C1.9–2.24187 / 187
Equipment / loop typeHP - Split System187 / 187
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)187 / 187
Compressor stagingTwo-stage187 / 187
Connected capabilityNo187 / 187

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*2412AM*+ furnace: PG96VTAB60080C**AHRI reference: 21875549516.008.00111002.05EPA 4706326 →
CSAH*2412AM*+ furnace: PG96VTAB48080B**AHRI reference: 21875549416.007.80110001.94EPA 4706327 →
CSAH*2412AM*+ furnace: PG96VTAB48060B**AHRI reference: 21875549316.008.00111002.05EPA 4706328 →
CSAH*2412AM*+ furnace: PG96VTAB36060A**AHRI reference: 21875549216.008.00111002.05EPA 4706329 →
CSAH*2412AM*+ furnace: PG95MSUA36040B**AHRI reference: 21875548616.007.80112002.00EPA 4706332 →
CSAH*2412AM*+ furnace: PG80VTLB66135D**AHRI reference: 21875548516.008.00111002.05EPA 4706333 →
CSAH*2412AM*+ furnace: PG80VTLB60090C**AHRI reference: 21875548316.008.00111002.05EPA 4706334 →
CSAH*2412AM*+ furnace: PG80VTLB48090B**AHRI reference: 21875548216.008.00111002.05EPA 4706335 →
CSAH*2412AM*+ furnace: PG80VTLB48070B**AHRI reference: 21875548116.007.80111001.92EPA 4706336 →
CSAH*2412AM*+ furnace: PG80VTLB36045A**AHRI reference: 21875547916.007.80110001.94EPA 4706337 →
CSAH*2412AM*+ furnace: PG80MSUA60100C**AHRI reference: 21875547816.007.80111002.00EPA 4706338 →
CSAH*2412AM*+ furnace: PG80MSUA36040B**AHRI reference: 21875547516.007.80110002.05EPA 4706339 →
CAA**3617AM*+ furnace: PG96VTAB30040A**AHRI reference: 21875544016.008.00112002.00EPA 4706374 →
CAA**3017AM*+ furnace: PG96VTAB36040B**AHRI reference: 21875542816.008.00112002.05EPA 4706386 →
CAA**3017AM*+ furnace: PG96VTAB30040A**AHRI reference: 21875542716.008.00112002.00EPA 4706387 →
CAA**3014AM*+ furnace: PG96VTAB30040A**AHRI reference: 21875541716.008.00112002.00EPA 4706397 →
CAA**2417AM*+ furnace: PG96VTAB36060A**AHRI reference: 21875539916.008.10111002.04EPA 4706415 →
CAA**2417AM*+ furnace: PG96VTAB36040B**AHRI reference: 21875539816.008.00113002.00EPA 4706416 →
CAA**3721AM*+TDRAHRI reference: 21875575815.507.80111001.94EPA 4706222 →
CAA**2517AM*+TDRAHRI reference: 21875575315.507.80111001.96EPA 4706223 →