WEATHERMAKER / AIR-SOURCE HEAT PUMP

PH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 6

204 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 204 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5204 / 204
EER2 · BTU/Wh11.5–14204 / 204
HSPF2 · BTU/Wh7.8–8.5204 / 204
Cooling capacity · BTU/h22,200–25,000204 / 204
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,200204 / 204
Heating capacity at 17°F / −8.3°C · BTU/h14,100–14,900204 / 204
Heating capacity at 5°F / −15°C · BTU/h10,700–11,400204 / 204
COP at 5°F / −15°C1.9–2.24204 / 204
Equipment / loop typeHP - Split System204 / 204
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)204 / 204
Compressor stagingTwo-stage204 / 204
Connected capabilityNo204 / 204

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2417AM*+ furnace: PG95MSUA48060B**AHRI reference: 21564408616.507.80110002.04EPA 3957572 →
CAA**2417AM*+ furnace: PG96VTAB48060B**AHRI reference: 21564425216.508.10110002.04EPA 3957690 →
CAA**2417AM*+ furnace: PG96VTAB48080B**AHRI reference: 21564428216.508.10110002.04EPA 3957702 →
CAA**2517AM*+ furnace: PG96VTAB30040A**AHRI reference: 21564497316.508.10113002.06EPA 3958188 →
CAA**2517AM*+ furnace: PG96VTAB36040B**AHRI reference: 21564500016.508.10113002.08EPA 3958203 →
CAA**3014AM*+ furnace: PG96VTAB36060A**AHRI reference: 21564536616.508.10109002.04EPA 3958423 →
CAA**3017AM*+ furnace: PG96VTAB36060A**AHRI reference: 21564603716.508.00111002.00EPA 3958610 →
CAA**3017AM*+ furnace: PG96VTAB48060B**AHRI reference: 21564606416.508.10110002.06EPA 3958628 →
CAA**3017AM*+ furnace: PG95MSUA36040B**AHRI reference: 21564586116.508.00111002.05EPA 3958861 →
CAA**3617AM*+ furnace: PG95MSUA36040B**AHRI reference: 21564665316.508.00110002.05EPA 3959417 →
CAA**3617AM*+ furnace: PG96VTAB36040B**AHRI reference: 21564679816.508.00111002.00EPA 3959511 →
CAA**3617AM*+ furnace: PG96VTAB36060A**AHRI reference: 21564682116.508.10111002.04EPA 3959526 →
CAA**3717AM*+ furnace: PG96VTAB36040B**AHRI reference: 21564758816.508.10113002.04EPA 3960042 →
CAA**3717AM*+ furnace: PG96VTAB30040A**AHRI reference: 21564756216.508.10114002.04EPA 3960247 →
CSAH*3012AM*+ furnace: PG80VTLB48070B**AHRI reference: 21565075916.507.80110002.08EPA 3962924 →
CSAH*3012AM*+ furnace: PG80VTLB48090B**AHRI reference: 21565078216.507.80110002.08EPA 3962932 →
CSAH*3012AM*+ furnace: PG80VTLB60090C**AHRI reference: 21565079716.508.00112002.06EPA 3962948 →
CSAH*3012AM*+ furnace: PG80VTLB66110C**AHRI reference: 21565082016.508.00111002.06EPA 3962960 →
CSAH*3012AM*+ furnace: PG80MSUA36040B**AHRI reference: 21565044016.508.00110002.08EPA 3963105 →
CSAH*3012AM*+ furnace: PG80MSUA48060B**AHRI reference: 21565046916.507.80111002.08EPA 3963125 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →