PH5SAN536**AA*
15 SEER2 HP
22 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH5SAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 22 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 22 / 22 |
| EER2 · BTU/Wh | 12–13 | 22 / 22 |
| HSPF2 · BTU/Wh | 7.8–8 | 22 / 22 |
| Cooling capacity · BTU/h | 33,800–36,800 | 22 / 22 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,400 | 22 / 22 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 22 / 22 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,100–18,100 | 22 / 22 |
| COP at 5°F / −15°C | 2–2.22 | 22 / 22 |
| Equipment / loop type | HP - Split System | 22 / 22 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 22 / 22 |
| Compressor staging | Single stage | 22 / 22 |
| Connected capability | No | 22 / 22 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 217051640 | 16.00 | 8.00 | 17400 | 2.18 | EPA 4001109 → |
PF5TNXC48L*AHRI reference: 214179939 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404462 → |
PF5MN*C48L*AHRI reference: 214180181 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3404798 → |
FEVB0048**+NAVA54801CKAHRI reference: 214277600 | 15.50 | 7.80 | 17400 | 2.22 | EPA 3415688 → |
FMA5X36**AL*AHRI reference: 214424292 | 15.50 | 7.80 | 17000 | 2.00 | EPA 3425181 → |
FJ5AN*C48L*AHRI reference: 218426622 | 15.50 | 7.80 | 17400 | 2.18 | EPA 4609759 → |
CAA**4321AM*+ furnace: PG80MS(A,L)A60110C**AHRI reference: 214139977 | 15.20 | 7.80 | 18000 | 2.20 | EPA 3400441 → |
CAA**4821AM*+ furnace: PG80VTLB60090C**AHRI reference: 214141946 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400612 → |
CAA**4821AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 214141341 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400767 → |
CAA**4321AM*+ furnace: PG92MSAA60100C**AHRI reference: 214140514 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3400788 → |
CAA**4821AM*+ furnace: PG80MS(A,L)A60110C**AHRI reference: 214141371 | 15.20 | 7.80 | 17600 | 2.20 | EPA 3400840 → |
CAA**4821AM*+ furnace: PG92MSAA60100C**AHRI reference: 214142260 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400872 → |
CVAMA4421XMA*+ furnace: PG80ESUA36040B**AHRI reference: 214143049 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3401013 → |
CAA**3721AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 214138231 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3401144 → |
CAA**4821AM*+ furnace: PG80MSUA48060B**AHRI reference: 214141633 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3401219 → |
CAA**4821AM*+ furnace: PG80MSUA60080C**AHRI reference: 214141665 | 15.20 | 7.80 | 17300 | 2.20 | EPA 3401262 → |
CAA**4321AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 214139947 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3401309 → |
CVAVA4224XMA*+ furnace: PG80MSUA60100C**AHRI reference: 214144594 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3401865 → |
PF5MN*C42L*AHRI reference: 214179897 | 15.20 | 7.80 | 16100 | 2.02 | EPA 3404666 → |
FM(C,U)5Z36**AL*AHRI reference: 215829104 | 15.20 | 7.80 | 17200 | 2.08 | EPA 3713517 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →