WEATHERMAKER / AIR-SOURCE HEAT PUMP

PH5SAN524**AA*

15 SEER2 HP · source records, page 5

118 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for PH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 118 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5118 / 118
EER2 · BTU/Wh11.7–13118 / 118
HSPF2 · BTU/Wh7.8–8.5118 / 118
Cooling capacity · BTU/h22,200–24,400118 / 118
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000118 / 118
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200118 / 118
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900118 / 118
COP at 5°F / −15°C1.98–2.26118 / 118
Equipment / loop typeHP - Split System118 / 118
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)118 / 118
Compressor stagingSingle stage118 / 118
Connected capabilityNo118 / 118

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
PF5MN*B30L*AHRI reference: 21417973815.207.80111002.06EPA 3404527
CAA**2517AM*+ furnace: PG80MS(A,L)A36045A**AHRI reference: 21419724215.207.80114002.10EPA 3405135
CAA**2517AM*+ furnace: PG80MS(A,L)A42045B**AHRI reference: 21419727415.207.80115002.10EPA 3405155
CAA**2517AM*+ furnace: PG80MS(A,L)A48070B**AHRI reference: 21419730215.207.80113002.12EPA 3405329
CAA**3617AM*+ furnace: PG80MS(A,L)A42090B**AHRI reference: 21419899115.207.80110002.02EPA 3405373
CAA**2517AM*+ furnace: PG95MSUA48060B**AHRI reference: 21419826115.207.80113002.12EPA 3405397
CAA**2517AM*+ furnace: PG80VTLB48070B**AHRI reference: 21419766715.207.80114002.10EPA 3405685
CAA**2517AM*+ furnace: PG80VTLB48090B**AHRI reference: 21419769515.207.80113002.12EPA 3405713
CAA**2517AM*+ furnace: PG96VTAB48060B**AHRI reference: 21419850015.207.80114002.10EPA 3405719
CAA**2517AM*+ furnace: PG96VTAB48080B**AHRI reference: 21419853315.207.80114002.10EPA 3405754
CAA**2517AM*+ furnace: PG96MSAA48080B**AHRI reference: 21419805915.207.80114002.10EPA 3405797
CAA**2517AM*+ furnace: PG92MSAA36060A**AHRI reference: 21419790115.207.80114002.10EPA 3406078
CAA**2517AM*+ furnace: PG92MSAA42060B**AHRI reference: 21419792915.207.80114002.12EPA 3406107
CAA**3717AM*+ furnace: PG80MS(A,L)A36070A**AHRI reference: 21419973115.207.80113002.10EPA 3406219
CAA**3717AM*+ furnace: PG80MS(A,L)A36070B**AHRI reference: 21419976315.207.80112002.10EPA 3406250
CAA**3721AM*+ furnace: PG80MS(A,L)A42045B**AHRI reference: 21420149515.207.80117002.12EPA 3406394
CAA**3717AM*+ furnace: PG96VTAB48080B**AHRI reference: 21420126415.207.80114002.08EPA 3406497
CAA**3717AM*+ furnace: PG80VTLB36070A**AHRI reference: 21420035415.207.80112002.08EPA 3406535
CAA**3717AM*+ furnace: PG80VTLB48070B**AHRI reference: 21420036615.207.80113002.08EPA 3406548
CAA**3717AM*+ furnace: PG96VTAB48060B**AHRI reference: 21420123115.207.80114002.08EPA 3406620