WEATHERMAKER / AIR-SOURCE HEAT PUMP

PH5SAN524**AA*

15 SEER2 HP

118 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for PH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 118 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5118 / 118
EER2 · BTU/Wh11.7–13118 / 118
HSPF2 · BTU/Wh7.8–8.5118 / 118
Cooling capacity · BTU/h22,200–24,400118 / 118
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000118 / 118
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200118 / 118
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900118 / 118
COP at 5°F / −15°C1.98–2.26118 / 118
Equipment / loop typeHP - Split System118 / 118
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)118 / 118
Compressor stagingSingle stage118 / 118
Connected capabilityNo118 / 118

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X30**AL*AHRI reference: 21442407616.508.50116002.26EPA 3425084 →
CVAVA3117XMA*+ furnace: PG80VTLB48090B**AHRI reference: 21420520916.007.80113001.98EPA 3408936 →
CVAMA3217XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21421273916.007.80113002.00EPA 3408989 →
CVAVA3817XMA*+ furnace: PG80VTLB48070B**AHRI reference: 21421435916.007.80114002.00EPA 3409015 →
CVAVA3817XMA*+ furnace: PG80VTLB48090B**AHRI reference: 21421438716.007.80114002.00EPA 3409041 →
CVAVA3721XMA*+ furnace: PG80MS(A,L)A48090C**AHRI reference: 21421339616.007.80112001.98EPA 3409070 →
CVAVA3817XMA*+ furnace: PG92MSAA42060B**AHRI reference: 21421448616.007.80114002.00EPA 3409646 →
CAA**3721AM*+ furnace: PG95MSUA60100C**AHRI reference: 21421197116.007.80115002.14EPA 3409821 →
CVAMA3217XMA*+ furnace: PG80VTLB48090B**AHRI reference: 21421289516.007.80114001.98EPA 3409897 →
CVAMA3217XMA*+ furnace: PG92MSAA48080B**AHRI reference: 21421299916.007.80112001.98EPA 3410187 →
CAA**2517AM*+ furnace: PG80MSUA36040B**AHRI reference: 21421053116.007.80113002.12EPA 3410504 →
CAA**2517AM*+ furnace: PG80MSUA48060B**AHRI reference: 21421056316.007.80112002.12EPA 3410535 →
CVAVA3817XMA*+ furnace: PG80MS(A,L)A36070B**AHRI reference: 21421397616.007.80114002.00EPA 3410637 →
CAA**3721AM*+ furnace: PG80VTLB66110C**AHRI reference: 21421149016.007.80115002.14EPA 3410742 →
CVAVA3817XMA*+ furnace: PG80MS(A,L)A48070B**AHRI reference: 21421400616.007.80114002.00EPA 3410766 →
CVAVA3817XMA*+ furnace: PG80MS(A,L)A42090B**AHRI reference: 21421403816.007.80112002.00EPA 3410797 →
CVAMA3117XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21421235116.007.80112001.98EPA 3410802 →
CVAVA3817XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21421423416.007.80112002.02EPA 3411136 →
CVAMA3217XMA*+ furnace: PG80MS(A,L)A42090B**AHRI reference: 21421254316.007.80112001.98EPA 3411157 →
CVAVA3117XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21421327516.007.80112002.00EPA 3411203 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →