PH5SAN519**AA*
15 SEER2 HP · source records, page 2
50 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH5SAN519**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 50 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 50 / 50 |
| EER2 · BTU/Wh | 12.5–13 | 50 / 50 |
| HSPF2 · BTU/Wh | 7.8–8 | 50 / 50 |
| Cooling capacity · BTU/h | 17,700–19,300 | 50 / 50 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,400–19,500 | 50 / 50 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,300–11,000 | 50 / 50 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,900–8,500 | 50 / 50 |
| COP at 5°F / −15°C | 1.9–2 | 50 / 50 |
| Equipment / loop type | HP - Split System | 50 / 50 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 50 / 50 |
| Compressor staging | Single stage | 50 / 50 |
| Connected capability | No | 50 / 50 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
PF5MN*B24L*AHRI reference: 217686911 | 15.50 | 7.80 | 8000 | 1.90 | EPA 4505899 → |
FMA5X18**AL*AHRI reference: 217687187 | 15.50 | 7.80 | 7900 | 2.00 | EPA 4506306 → |
FMA5X24**AL*AHRI reference: 217687219 | 15.50 | 7.80 | 7900 | 2.00 | EPA 4506407 → |
PF5TNXB24L*AHRI reference: 217687262 | 15.50 | 7.80 | 8100 | 1.95 | EPA 4506464 → |
FM(C,U)5Z18**AL*AHRI reference: 217687027 | 15.50 | 7.80 | 8100 | 2.00 | EPA 4506524 → |
FM(C,U)5Z24**AL*AHRI reference: 217687059 | 15.50 | 7.80 | 8100 | 2.00 | EPA 4506565 → |
CAA**1917AM*+ furnace: PG80VTLB48070B**AHRI reference: 217702310 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4507442 → |
CAA**1917AM*+ furnace: PG80VTLB48090B**AHRI reference: 217702333 | 15.50 | 8.00 | 8300 | 2.00 | EPA 4507465 → |
CAA**2517AM*+ furnace: PG96MSAA36060A**AHRI reference: 217705605 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4507504 → |
CAA**2517AM*+ furnace: PG96MSAA48080B**AHRI reference: 217705628 | 15.50 | 8.00 | 8500 | 2.00 | EPA 4507528 → |
CAA**2517AM*+ furnace: PG95MSUA36040B**AHRI reference: 217705735 | 15.50 | 7.80 | 8400 | 1.90 | EPA 4507635 → |
CAA**1917AM*+ furnace: PG97VTAA48060B**AHRI reference: 217703060 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4507685 → |
CAA**1917AM*+ furnace: PG97VTAA48080B**AHRI reference: 217703083 | 15.50 | 8.00 | 8300 | 2.00 | EPA 4507708 → |
CAA**1917AM*+ furnace: PG92MSAA36060A**AHRI reference: 217702452 | 15.50 | 8.00 | 8300 | 2.00 | EPA 4507749 → |
CAA**2517AM*+ furnace: PG80MS(A,L)A42045B**AHRI reference: 217704943 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4507898 → |
CAA**1917AM*+ furnace: PG96MSAA36060A**AHRI reference: 217702602 | 15.50 | 8.00 | 8400 | 1.98 | EPA 4508134 → |
CAA**2517AM*+ furnace: PG96VTAB36060A**AHRI reference: 217705949 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4508145 → |
CAA**2517AM*+ furnace: PG96VTAB48060B**AHRI reference: 217705974 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4508170 → |
CAA**2517AM*+ furnace: PG97VTAA48060B**AHRI reference: 217705999 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4508267 → |
CAA**1917AM*+ furnace: PG96MSAA48080B**AHRI reference: 217702654 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4508326 → |