Tempstar / AIR-SOURCE HEAT PUMP

T5H8T48*K*AAA*

Mainline 18 SEER2 HP · source records, page 5

415 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for T5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18415 / 415
EER2 · BTU/Wh11.7–13.5415 / 415
HSPF2 · BTU/Wh7.8–8.5415 / 415
Cooling capacity · BTU/h45,500–50,500415 / 415
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500415 / 415
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400415 / 415
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600415 / 415
COP at 5°F / −15°C2.1–2.34415 / 415
Equipment / loop typeHP - Split System415 / 415
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)415 / 415
Compressor stagingTwo-stage415 / 415
Connected capabilityNo415 / 415

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635086117.508.00236002.16EPA 3807518 →
EVD5X60M21A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21635090117.508.00238002.18EPA 3807558 →
EVD5X61M21A*+WALLCON+ furnace: *80CTL0702120B*AHRI reference: 21635105317.508.00238002.16EPA 4000706 →
QFVA5D4821X*AHRI reference: 21869561917.508.10254002.18EPA 4683208 →
EVM5X48M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21634968517.008.00232002.18EPA 3803276 →
EVD5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 21635119017.008.10250002.14EPA 3803328 →
EVD5X61M21A*+ furnace: *96VTN1002120B*AHRI reference: 21635119817.008.10250002.16EPA 3803336 →
EVD5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21635113417.008.10250002.14EPA 3803339 →
EVD5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635114217.008.10250002.16EPA 3803347 →
EVD5X48M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21635049317.008.00232002.18EPA 3803385 →
EVM5X49M21A*+ furnace: *80MSU1002120A*AHRI reference: 21634977317.008.10248002.14EPA 3803398 →
EVM5X49M21A*+ furnace: *80VTL0902120B*AHRI reference: 21634980517.008.10250002.14EPA 3803422 →
EVD5X48M21A*+ furnace: *97VTN1002122A*AHRI reference: 21635054117.008.00240002.16EPA 3803495 →
EVD5X49M24A*+ furnace: *80VSL0902120B*AHRI reference: 21635054917.008.10250002.12EPA 3803504 →
EVD5X49M24A*+ furnace: *80VSL1102122B*AHRI reference: 21635055717.008.10250002.14EPA 3803512 →
EVD5X49M24A*+ furnace: *95MSU1002122A*AHRI reference: 21635065317.008.10248002.16EPA 3803521 →
EVD5X49M24A*+ furnace: *80VSL1352422B*AHRI reference: 21635056517.008.10250002.14EPA 3803527 →
EVD5X61M21A*+ furnace: *97VTN0802120A*AHRI reference: 21635124617.008.00250002.10EPA 3803595 →
EVD5X61M21A*+ furnace: *97VTN1002120A*AHRI reference: 21635125417.008.00250002.12EPA 3803610 →
EVM5X49M21A*+ furnace: *95MSU1002120A*AHRI reference: 21634987717.008.10252002.12EPA 3803772 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →