T5H8T48*K*AAA*
Mainline 18 SEER2 HP · source records, page 12
415 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for T5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 415 / 415 |
| EER2 · BTU/Wh | 11.7–13.5 | 415 / 415 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 415 / 415 |
| Cooling capacity · BTU/h | 45,500–50,500 | 415 / 415 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 415 / 415 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–32,400 | 415 / 415 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,200–26,600 | 415 / 415 |
| COP at 5°F / −15°C | 2.1–2.34 | 415 / 415 |
| Equipment / loop type | HP - Split System | 415 / 415 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 415 / 415 |
| Compressor staging | Two-stage | 415 / 415 |
| Connected capability | No | 415 / 415 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 216350277 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3806622 → |
EVD5X48M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 216350389 | 16.50 | 8.00 | 23600 | 2.16 | EPA 3806630 → |
EVD5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 216350285 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3806639 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 216352590 | 16.50 | 8.00 | 24800 | 2.26 | EPA 3806661 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 216352598 | 16.50 | 8.00 | 25000 | 2.24 | EPA 3806669 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 216352710 | 16.50 | 8.00 | 25000 | 2.24 | EPA 3806685 → |
EA*5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 216352526 | 16.50 | 8.10 | 25600 | 2.24 | EPA 3806858 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 216352566 | 16.50 | 8.10 | 25200 | 2.26 | EPA 3806882 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 216352574 | 16.50 | 8.00 | 25000 | 2.24 | EPA 3806890 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0601716B*AHRI reference: 216352582 | 16.50 | 8.00 | 25200 | 2.24 | EPA 3806898 → |
EVM5X48M21A*+ furnace: *95MSU1002120A*AHRI reference: 216349629 | 16.50 | 8.10 | 24400 | 2.14 | EPA 3806944 → |
EVM5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 216349637 | 16.50 | 8.10 | 24600 | 2.14 | EPA 3806953 → |
EVD5X48M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 216350365 | 16.50 | 8.00 | 23400 | 2.18 | EPA 3806972 → |
EVD5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 216350341 | 16.50 | 8.10 | 24400 | 2.14 | EPA 3806982 → |
EVD5X48M21A*+ furnace: *96VTN1002120B*AHRI reference: 216350461 | 16.50 | 8.10 | 24400 | 2.16 | EPA 3807027 → |
EVD5X48M21A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 216350501 | 16.50 | 8.00 | 23400 | 2.16 | EPA 3807037 → |
EVD5X48M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 216350517 | 16.50 | 8.00 | 23600 | 2.16 | EPA 3807045 → |
EVD5X49M24A*+ furnace: *96VSN1202422B*AHRI reference: 216350637 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3807050 → |
EVM5X48M21A*+ furnace: *97VTN1002122A*AHRI reference: 216349725 | 16.50 | 8.00 | 24200 | 2.12 | EPA 3807108 → |
EVD5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 216351150 | 16.50 | 8.10 | 25200 | 2.14 | EPA 3807172 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →