Tempstar / AIR-SOURCE HEAT PUMP

T5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 4

498 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for T5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FCMA5X24L0B*+WALLCONAHRI reference: 21636891317.508.10111002.08EPA 3809331
EA*5X36M17A*+ furnace: *80VTL0451412B*AHRI reference: 21636571817.508.10109002.10EPA 3809355
EA*5X37M17A*+ furnace: *80VSL0701716B*AHRI reference: 21636603617.508.10112002.10EPA 3809365
EA*5X30M17A*+ furnace: *80MSU0601716A*AHRI reference: 21636535017.507.80109002.02EPA 3809446
EA*5X37M17A*+ furnace: *80VSL0901716B*AHRI reference: 21636604717.508.10110002.12EPA 3809463
EA*5X37M17A*+ furnace: *80MSU0401712A*AHRI reference: 21636605717.508.10110002.10EPA 3809496
EA*5X37M21A*+WALLCON+ furnace: *97CMN0801714B*AHRI reference: 21636659117.508.10113002.10EPA 3809503
EA*5X37M21A*+ furnace: *96VSN0801716B*AHRI reference: 21636663117.508.10112002.10EPA 3809548
EA*5X37M17A*+ furnace: *80MSU0601716A*AHRI reference: 21636606717.508.10111002.12EPA 3809564
EA*5X37M17A*+WALLCON+ furnace: *80CTL0701412B*AHRI reference: 21636608917.508.00112002.08EPA 3809631
EA*5X37M17A*+ furnace: *80VSL0451412B*AHRI reference: 21636601617.508.10111002.10EPA 3809649
EA*5X37M17A*+ furnace: *80VSL0701412B*AHRI reference: 21636602717.508.10111002.10EPA 3809659
EA*5X37M21A*+ furnace: OMV098J12*AHRI reference: 21636678317.508.10115002.08EPA 3809665
EA*5X37M21A*+ furnace: OMV112K14AAHRI reference: 21636679117.508.10115002.08EPA 3809673
EA*5X37M21A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 21636682317.508.10113002.12EPA 3809705
EA*5X25M17A*+WALLCON+ furnace: *96CTN0601714B*AHRI reference: 21636509417.508.00113002.08EPA 3809861
EA*5X25M17A*+WALLCON+ furnace: *96CTN0801714B*AHRI reference: 21636510217.508.00112002.08EPA 3809869
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 21636513417.508.10112002.10EPA 3809901
EA*5X25M17A*+ furnace: *96VTN0801716B*AHRI reference: 21636514217.508.10111002.10EPA 3809909
EA*5X37M21A*+ furnace: *97VTN1002120A*AHRI reference: 21636688717.508.00111002.10EPA 3810017

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →