T5H8T24*K*AAA*
Mainline 18 SEER2 HP · source records, page 25
498 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for T5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 498 / 498 |
| EER2 · BTU/Wh | 11.7–14 | 498 / 498 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 498 / 498 |
| Cooling capacity · BTU/h | 22,200–25,000 | 498 / 498 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–25,400 | 498 / 498 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,100–15,000 | 498 / 498 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,700–11,500 | 498 / 498 |
| COP at 5°F / −15°C | 1.94–2.24 | 498 / 498 |
| Equipment / loop type | HP - Split System | 498 / 498 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 498 / 498 |
| Compressor staging | Two-stage | 498 / 498 |
| Connected capability | No | 498 / 498 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X30M12A*+WALLCON+ furnace: *97CMN0602120B*AHRI reference: 216367792 | 16.00 | 8.00 | 11200 | 2.06 | EPA 3812821 → |
ESH5X24M12A*+ furnace: *96VTN0601412B*AHRI reference: 216367351 | 15.50 | 7.80 | 11100 | 2.00 | EPA 3809721 → |
EA*5X24M14A*+WALLCON+ furnace: *96CTN0401410B*AHRI reference: 216364542 | 15.50 | 8.00 | 11400 | 1.98 | EPA 3809733 → |
EA*5X24M14A*+ furnace: *96VTN0401410B*AHRI reference: 216364550 | 15.50 | 8.10 | 11200 | 2.04 | EPA 3809742 → |
ESH5X30M12A*+ furnace: OLV098A12*AHRI reference: 216368113 | 15.50 | 7.80 | 11500 | 1.98 | EPA 3809849 → |
EA*5X24M17A*+ furnace: *96VSN0401410B*AHRI reference: 216364702 | 15.50 | 7.80 | 11400 | 1.96 | EPA 3810350 → |
EA*5X30M17A*+ furnace: *96VTN0401410B*AHRI reference: 216365510 | 15.50 | 7.80 | 11200 | 1.96 | EPA 3811123 → |
ESH5X24M12A*+ furnace: *96VSN0601412B*AHRI reference: 216367199 | 15.50 | 7.80 | 11100 | 2.00 | EPA 3811596 → |
EA*5X25M17A*+TDRAHRI reference: 216364422 | 15.50 | 7.80 | 11100 | 2.02 | EPA 3811622 → |
EA*5X37M21A*+TDRAHRI reference: 216364462 | 15.50 | 7.80 | 11100 | 2.02 | EPA 3811630 → |
ESH5X30M12A*+ furnace: *97VTN0601716A*AHRI reference: 216368209 | 15.50 | 7.80 | 11100 | 2.00 | EPA 3811775 → |
ESH5X30M12A*+ furnace: *97VTN0801716A*AHRI reference: 216368217 | 15.50 | 7.80 | 11100 | 2.02 | EPA 3811902 → |
ESH5X30M12A*+ furnace: *97VTN0802120A*AHRI reference: 216368225 | 15.50 | 7.80 | 11100 | 2.02 | EPA 3811955 → |
ESH5X30M12A*+ furnace: *97VTN1002120A*AHRI reference: 216368233 | 15.50 | 7.80 | 11000 | 2.02 | EPA 3812092 → |
ESH5X30M12A*+ furnace: *96VTN0401712B*AHRI reference: 216368049 | 15.50 | 7.80 | 11300 | 2.00 | EPA 3812117 → |
EA*5X24M17A*+ furnace: *96VTN0401410B*AHRI reference: 216364782 | 15.50 | 7.80 | 11300 | 1.94 | EPA 3812573 → |
ESH5X30M12A*+ furnace: *96VSN0401712B*AHRI reference: 216367856 | 15.50 | 7.80 | 11300 | 2.00 | EPA 3812861 → |
ESH5X24M12A*+ furnace: *96VSN0401410B*AHRI reference: 216367183 | 15.20 | 7.80 | 11200 | 1.98 | EPA 3811588 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.