Tempstar / AIR-SOURCE HEAT PUMP

T5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 17

498 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for T5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X36M12A*+WALLCON+ furnace: *97CMN1202422B*AHRI reference: 21636852916.508.00111002.08EPA 3811059
EA*5X30M17A*+ furnace: *96VSN0601716B*AHRI reference: 21636545416.508.10110002.08EPA 3811066
EA*5X30M17A*+ furnace: *95MSU0401712A*AHRI reference: 21636547016.507.80111002.00EPA 3811082
EA*5X37M17A*+ furnace: *96VTN0401410B*AHRI reference: 21636627916.508.10114002.08EPA 3811138
EA*5X37M17A*+ furnace: *96VTN0401712B*AHRI reference: 21636628716.508.10113002.08EPA 3811145
ESH5X30M12A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 21636776716.508.00112002.06EPA 3811240
ESH5X30M12A*+WALLCON+ furnace: *80CTL1352422B*AHRI reference: 21636771916.508.00112002.06EPA 3811254
ESH5X30M12A*+ furnace: *80VTL0451412B*AHRI reference: 21636772716.507.80111002.02EPA 3811262
ESH5X30M12A*+ furnace: *80VTL0701716B*AHRI reference: 21636773516.507.80110002.02EPA 3811272
ESH5X30M12A*+ furnace: *80VTL0902120B*AHRI reference: 21636774316.508.00112002.06EPA 3811280
ESH5X30M12A*+ furnace: *80VTL1102122B*AHRI reference: 21636775116.508.00111002.06EPA 3811288
ESH5X30M12A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21636777616.508.00111002.06EPA 3811304
ESH5X36M12A*+ furnace: *96VSN1002120B*AHRI reference: 21636858516.508.00110002.08EPA 3811318
ESH5X36M12A*+ furnace: *96VSN0601716B*AHRI reference: 21636856116.507.80110002.04EPA 3811319
ESH5X36M12A*+WALLCON+ furnace: *96CTN1202422B*AHRI reference: 21636868116.508.00111002.08EPA 3811333
ESH5X36M12A*+ furnace: *95MSU0802120A*AHRI reference: 21636861716.507.80110002.02EPA 3811341
EA*5X30M17A*+ furnace: *96VTN0601412B*AHRI reference: 21636552616.507.80111001.98EPA 3811357
EA*5X30M17A*+ furnace: *96VTN0601716B*AHRI reference: 21636553416.508.10110002.08EPA 3811365
EA*5X30M17A*+ furnace: OLV098A12*AHRI reference: 21636555016.508.10112002.04EPA 3811381
EA*5X30M17A*+ furnace: OMV098J12*AHRI reference: 21636555816.507.80112001.96EPA 3811388