Tempstar / AIR-SOURCE HEAT PUMP

T5H6S31*K*AAA*

MAINLINE 16 SEER2 HP · source records, page 2

38 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity27,400–29,400BTU/h

Each efficiency range summarizes published EPA records for T5H6S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 38 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1638 / 38
EER2 · BTU/Wh11.7–1338 / 38
HSPF2 · BTU/Wh7.8–838 / 38
Cooling capacity · BTU/h27,400–29,40038 / 38
Heating capacity at 47°F / 8.3°C · BTU/h29,200–30,60038 / 38
Heating capacity at 17°F / −8.3°C · BTU/h17,300–18,20038 / 38
Heating capacity at 5°F / −15°C · BTU/h13,100–14,00038 / 38
COP at 5°F / −15°C2–2.0638 / 38
Equipment / loop typeHP - Split System38 / 38
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)38 / 38
Compressor stagingSingle stage38 / 38
Connected capabilityNo38 / 38

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X43M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 21771787815.508.00139002.06EPA 4509310 →
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21771795815.508.00140002.06EPA 4509337 →
EA*5X43M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21771789415.508.00139002.04EPA 4509347 →
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21771796615.508.00140002.04EPA 4509353 →
FCMA5B36L0C*+WALLCONAHRI reference: 21772140715.507.80131002.05EPA 4509361 →
FEVA0036**+NAVA53601CKAHRI reference: 21772141515.507.80134002.00EPA 4509369 →
FEVB0036**+NAVA53601CKAHRI reference: 21772142315.507.80134002.00EPA 4509377 →
F5MA5*30L*B*AHRI reference: 21772143115.507.80134002.00EPA 4509385 →
EA*5X43M21A*+ furnace: *80VSL1102122B*AHRI reference: 21771799815.508.00140002.06EPA 4509393 →
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 21771801415.508.00140002.06EPA 4509401 →
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 21771802215.508.00140002.06EPA 4509409 →
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 21771819815.508.00140002.06EPA 4509472 →
EA*5X43M21A*+ furnace: *92MSN1002122A*AHRI reference: 21771820615.508.00140002.06EPA 4509480 →
EA*5X43M21A*+ furnace: *92MSN0802120A*AHRI reference: 21771819015.508.00140002.06EPA 4509553 →
EA*5X43M21A*+ furnace: *95MSU1002122A*AHRI reference: 21771831215.508.00140002.06EPA 4509619 →
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 21771841615.508.00140002.06EPA 4509792 →
EA*5X43M21A*+ furnace: *97VTN1002122A*AHRI reference: 21771845615.508.00140002.06EPA 4509800 →
FMA5L30**AL*AHRI reference: 21772149615.208.00138002.00EPA 4509445 →