T5H6S31*K*AAA*
MAINLINE 16 SEER2 HP · source records, page 2
38 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for T5H6S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 38 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 38 / 38 |
| EER2 · BTU/Wh | 11.7–13 | 38 / 38 |
| HSPF2 · BTU/Wh | 7.8–8 | 38 / 38 |
| Cooling capacity · BTU/h | 27,400–29,400 | 38 / 38 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,200–30,600 | 38 / 38 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,300–18,200 | 38 / 38 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,100–14,000 | 38 / 38 |
| COP at 5°F / −15°C | 2–2.06 | 38 / 38 |
| Equipment / loop type | HP - Split System | 38 / 38 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 38 / 38 |
| Compressor staging | Single stage | 38 / 38 |
| Connected capability | No | 38 / 38 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X43M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 217717878 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4509310 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 217717958 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509337 → |
EA*5X43M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 217717894 | 15.50 | 8.00 | 13900 | 2.04 | EPA 4509347 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 217717966 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4509353 → |
FCMA5B36L0C*+WALLCONAHRI reference: 217721407 | 15.50 | 7.80 | 13100 | 2.05 | EPA 4509361 → |
FEVA0036**+NAVA53601CKAHRI reference: 217721415 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4509369 → |
FEVB0036**+NAVA53601CKAHRI reference: 217721423 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4509377 → |
F5MA5*30L*B*AHRI reference: 217721431 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4509385 → |
EA*5X43M21A*+ furnace: *80VSL1102122B*AHRI reference: 217717998 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509393 → |
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 217718014 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509401 → |
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 217718022 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509409 → |
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 217718198 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509472 → |
EA*5X43M21A*+ furnace: *92MSN1002122A*AHRI reference: 217718206 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509480 → |
EA*5X43M21A*+ furnace: *92MSN0802120A*AHRI reference: 217718190 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509553 → |
EA*5X43M21A*+ furnace: *95MSU1002122A*AHRI reference: 217718312 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509619 → |
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 217718416 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509792 → |
EA*5X43M21A*+ furnace: *97VTN1002122A*AHRI reference: 217718456 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4509800 → |
FMA5L30**AL*AHRI reference: 217721496 | 15.20 | 8.00 | 13800 | 2.00 | EPA 4509445 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →