Tempstar / AIR-SOURCE HEAT PUMP

T5H6S24*K*AAA*

MAINLINE 16 SEER2 HP · source records, page 2

193 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for T5H6S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 193 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5193 / 193
EER2 · BTU/Wh11.7–13193 / 193
HSPF2 · BTU/Wh7.8–8.5193 / 193
Cooling capacity · BTU/h22,200–24,400193 / 193
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000193 / 193
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200193 / 193
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900193 / 193
COP at 5°F / −15°C1.98–2.26193 / 193
Equipment / loop typeHP - Split System193 / 193
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)193 / 193
Compressor stagingSingle stage193 / 193
Connected capabilityNo193 / 193

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *80CTL0902120B*AHRI reference: 21416114816.007.80115002.14EPA 3403702 →
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21416116416.007.80115002.14EPA 3403718 →
EA*5X37M21A*+ furnace: *97CMN1002122A*AHRI reference: 21416118816.007.80112002.12EPA 3403730 →
EA*5X37M21A*+ furnace: *97CMN0802120B*AHRI reference: 21416119616.007.80115002.14EPA 3403737 →
EA*5X37M21A*+ furnace: *97CMN1002122B*AHRI reference: 21416120416.007.80115002.14EPA 3403746 →
EA*5X37M21A*+ furnace: *95MSU1002120A*AHRI reference: 21416130016.007.80115002.14EPA 3403892 →
EA*5X37M21A*+ furnace: *96CTN1002122A*AHRI reference: 21416131616.007.80112002.12EPA 3403942 →
EA*5X37M21A*+ furnace: *96CTN0802120B*AHRI reference: 21416132416.007.80115002.14EPA 3403950 →
EA*5X37M21A*+ furnace: *96CTN1002122B*AHRI reference: 21416133216.007.80115002.14EPA 3403958 →
EVD5X38M17A*+ furnace: *80MSU0601716A*AHRI reference: 21416190016.007.80113002.02EPA 3404263 →
EVD5X38M17A*+ furnace: *80VTL0701716B*AHRI reference: 21416193216.007.80114002.00EPA 3404271 →
EVD5X38M17A*+ furnace: *92MSN0601714A*AHRI reference: 21416196416.007.80114002.00EPA 3404302 →
EA*5X37M21A*+ furnace: *97VTN1002120A*AHRI reference: 21580239216.008.00115002.10EPA 3653617 →
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 21580240016.008.00114002.10EPA 3653625 →
FM(C,U)5Z30**AL*AHRI reference: 21582900616.007.80111001.98EPA 3713420 →
FM(C,U)5Z36**AL*AHRI reference: 21582901416.007.80111001.98EPA 3713428 →
EA*5X37M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21700669916.007.80115002.14EPA 3997997 →
EA*5X37M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21700671516.007.80116002.14EPA 3998013 →
EA*5X25M17A*+WALLCON+ furnace: *80CTL0701412B*AHRI reference: 21700668316.007.80114002.12EPA 3998021 →
EA*5X37M21A*+WALLCON+ furnace: *97CMN0802120B*AHRI reference: 21700672316.007.80115002.14EPA 3998030 →