T5H6S18*K*AAA*
MAINLINE 16 SEER2 HP
46 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for T5H6S18*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 46 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–15.5 | 46 / 46 |
| EER2 · BTU/Wh | 11.7–12.5 | 46 / 46 |
| HSPF2 · BTU/Wh | 7.8–8 | 46 / 46 |
| Cooling capacity · BTU/h | 17,400–18,900 | 46 / 46 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,400–18,100 | 46 / 46 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,500–10,900 | 46 / 46 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,200–8,500 | 46 / 46 |
| COP at 5°F / −15°C | 1.94–2.1 | 46 / 46 |
| Equipment / loop type | HP - Split System | 46 / 46 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 46 / 46 |
| Compressor staging | Single stage | 46 / 46 |
| Connected capability | No | 46 / 46 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X32M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 214156830 | 15.50 | 7.80 | 8200 | 1.94 | EPA 3403191 → |
EVM5X32M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 214156838 | 15.50 | 7.80 | 8200 | 1.94 | EPA 3403430 → |
FMA5X24**AL*AHRI reference: 214423970 | 15.50 | 8.00 | 8200 | 2.10 | EPA 3425284 → |
EA*5X25M17A*+ furnace: *80VSL0451412B*AHRI reference: 214150718 | 15.20 | 7.80 | 8400 | 2.04 | EPA 3401373 → |
EA*5X25M17A*+ furnace: *80VSL0701716B*AHRI reference: 214150734 | 15.20 | 7.80 | 8400 | 2.04 | EPA 3401381 → |
EA*5X25M17A*+ furnace: *80ESU0401712A*AHRI reference: 214150750 | 15.20 | 7.80 | 8400 | 2.06 | EPA 3401389 → |
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 214150766 | 15.20 | 7.80 | 8400 | 2.06 | EPA 3401405 → |
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 214150774 | 15.20 | 7.80 | 8400 | 2.06 | EPA 3401413 → |
EA*5X25M17A*+ furnace: *80CTL0701412B*AHRI reference: 214150791 | 15.20 | 7.80 | 8400 | 2.06 | EPA 3401456 → |
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 214150799 | 15.20 | 7.80 | 8500 | 2.04 | EPA 3401465 → |
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 214150807 | 15.20 | 7.80 | 8500 | 2.04 | EPA 3401473 → |
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 214150823 | 15.20 | 7.80 | 8400 | 2.04 | EPA 3401481 → |
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 214150831 | 15.20 | 7.80 | 8500 | 2.04 | EPA 3401488 → |
EA*5X25M17A*+ furnace: *92MSN0601714A*AHRI reference: 214150903 | 15.20 | 7.80 | 8400 | 2.04 | EPA 3401532 → |
EA*5X25M17A*+ furnace: *92MSN0801716A*AHRI reference: 214150911 | 15.20 | 7.80 | 8400 | 2.06 | EPA 3401540 → |
EA*5X25M17A*+ furnace: *96MSN0801716A*AHRI reference: 214150927 | 15.20 | 7.80 | 8500 | 2.04 | EPA 3401549 → |
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 214150959 | 15.20 | 7.80 | 8500 | 2.04 | EPA 3401554 → |
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 214150975 | 15.20 | 7.80 | 8400 | 2.04 | EPA 3401563 → |
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 214150999 | 15.20 | 7.80 | 8400 | 2.04 | EPA 3401573 → |
EA*5X19M17A*+ furnace: *80MSU0401712A*AHRI reference: 214150389 | 15.20 | 7.80 | 8400 | 2.04 | EPA 3401618 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.