Tempstar / AIR-SOURCE HEAT PUMP

T5H3V48*K*AAA*

SmartSense 23 VS HP · source records, page 2

138 published source records · source checked Sep 21, 2026

SEER2 range19.5–23BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity43,000–46,500BTU/h

Each efficiency range summarizes published EPA records for T5H3V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 138 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh19.5–23138 / 138
EER2 · BTU/Wh10–12.5138 / 138
HSPF2 · BTU/Wh8–9.5138 / 138
Cooling capacity · BTU/h43,000–46,500138 / 138
Heating capacity at 47°F / 8.3°C · BTU/h48,000–53,500135 / 138
Heating capacity at 17°F / −8.3°C · BTU/h39,000–43,500138 / 138
Heating capacity at 5°F / −15°C · BTU/h35,600–38,500138 / 138
COP at 5°F / −15°C1.8–2138 / 138
Equipment / loop typeHP - Split System138 / 138
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)138 / 138
Compressor stagingContinuously variable138 / 138
Connected capabilityNo138 / 138

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X61M24A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21593760321.008.00380001.92EPA 3725399
EVM5X61M24A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21593761321.008.00380001.92EPA 3725545
EVM5X61M24A*+WALLCON+ furnace: *80CTL1352422B*AHRI reference: 21593762321.008.00380001.92EPA 3725555
EVM5X61M24A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21593764321.008.00380001.92EPA 3725565
EVD5X49M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21593802321.008.10380001.95EPA 3725766
EVD5X49M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21593803321.008.10380001.95EPA 3725783
EVD5X61M24A*+WALLCON+ furnace: *80CTL1352422B*AHRI reference: 21593860321.008.00380001.92EPA 3725949
EVD5X61M24A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21593862321.008.00380001.92EPA 3725959
EA*5X61M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21593422321.009.50370002.00EPA 3726259
EVD5X49M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21593804321.008.10380001.95EPA 3726842
EA*5X61M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21593429321.009.50368002.00EPA 3726939
EA*5X61M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21593426321.009.50370002.00EPA 3726961
EA*5X61M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21593427321.009.50368002.00EPA 3726971
EA*5X61M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 21593430321.009.50368002.00EPA 3727536
EA*5X48M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21593404321.009.50362002.00EPA 3728300
EVD5X60M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21593832321.008.10380001.95EPA 3729991
EA*5X48M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21593401321.009.50362001.92EPA 3730138
EA*5X48M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21593402321.009.50364001.92EPA 3730148
EVD5X61M24A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21593858321.008.00380001.92EPA 3732157
EA*5X60M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 21593409321.009.50364002.00EPA 3732338

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →