T5H0V60*K*AAA*
SmartSense 20 VS HP · source records, page 4
158 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for T5H0V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 158 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–19 | 158 / 158 |
| EER2 · BTU/Wh | 8–9.8 | 158 / 158 |
| HSPF2 · BTU/Wh | 8.1–9 | 158 / 158 |
| Cooling capacity · BTU/h | 54,000–58,000 | 158 / 158 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 59,000–63,500 | 54 / 158 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 50,500–57,500 | 158 / 158 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–46,000 | 158 / 158 |
| COP at 5°F / −15°C | 1.86–2.1 | 158 / 158 |
| Equipment / loop type | HP - Split System | 158 / 158 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 158 / 158 |
| Compressor staging | Continuously variable | 158 / 158 |
| Connected capability | No | 158 / 158 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215677992 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3973335 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215678002 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3973337 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215678012 | 18.50 | 9.00 | 42000 | 2.00 | EPA 3973357 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215678022 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3973360 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215678032 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3973370 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215682582 | 18.50 | 9.00 | 42000 | 1.90 | EPA 3977533 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215682592 | 18.50 | 8.50 | 41000 | 2.04 | EPA 3977543 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682612 | 18.50 | 9.00 | 42000 | 1.90 | EPA 3977567 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682622 | 18.50 | 9.00 | 41500 | 1.90 | EPA 3977576 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682632 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3977579 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215682662 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3977938 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682692 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3978022 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682702 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3978035 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682712 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3978051 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682862 | 18.50 | 9.00 | 45000 | 2.08 | EPA 3978219 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215683052 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978240 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215683102 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978283 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215683232 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978313 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682912 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978345 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682922 | 18.50 | 9.00 | 44500 | 2.10 | EPA 3978365 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →