T5H0V48*K*AAA*
SmartSense 20 VS HP · source records, page 2
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for T5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682082 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3976603 → |
EVM5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682092 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3976749 → |
EVD5X61M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682512 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3977467 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682562 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3977511 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682572 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3977515 → |
FCMA5B48L0C*+WALLCONCold climate designationAHRI reference: 215662878 | 19.00 | 9.00 | 33600 | 2.10 | EPA 3967089 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675882 | 19.00 | 9.00 | 36400 | 2.00 | EPA 3968661 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215675892 | 19.00 | 9.00 | 36400 | 2.00 | EPA 3968668 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215675812 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3968806 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215675822 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3968812 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215675842 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3968837 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215675852 | 19.00 | 9.00 | 36400 | 2.12 | EPA 3968847 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215675872 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3968867 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215675682 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3968940 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215675722 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3968980 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215675732 | 19.00 | 9.00 | 37000 | 1.98 | EPA 3968996 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675742 | 19.00 | 9.50 | 36600 | 2.10 | EPA 3969003 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215675552 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3969090 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215675562 | 19.00 | 9.00 | 37000 | 1.98 | EPA 3969098 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675572 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3969104 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.