T5H0V48*K*AAA*
SmartSense 20 VS HP · source records, page 14
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for T5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X48M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215675422 | 18.00 | 9.00 | 36600 | 1.98 | EPA 3969159 → |
EVM5X48M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215675432 | 18.00 | 9.00 | 36400 | 2.02 | EPA 3969172 → |
EVM5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215675442 | 18.00 | 9.00 | 37000 | 1.98 | EPA 3969182 → |
EVM5X48M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 215675472 | 18.00 | 9.00 | 35600 | 2.00 | EPA 3969280 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 215675532 | 18.00 | 9.00 | 37600 | 1.98 | EPA 3969337 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215675762 | 18.00 | 9.00 | 37200 | 1.98 | EPA 3969363 → |
EVD5X48M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 215676122 | 18.00 | 9.00 | 36800 | 1.98 | EPA 3969851 → |
EVD5X48M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 215676162 | 18.00 | 9.00 | 35600 | 2.00 | EPA 3969945 → |
EVD5X48M21A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215676102 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3970065 → |
EVD5X48M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215676242 | 18.00 | 9.00 | 36600 | 2.02 | EPA 3970088 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 215676442 | 18.00 | 9.00 | 37600 | 1.98 | EPA 3970826 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215676502 | 18.00 | 9.00 | 37200 | 1.98 | EPA 3970886 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215681552 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975274 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681762 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3975554 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215681772 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3975567 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681792 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3975581 → |
EVM5X48M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 215681802 | 18.00 | 9.00 | 37000 | 2.00 | EPA 3975739 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215681372 | 18.00 | 9.00 | 34000 | 2.04 | EPA 3975835 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215681382 | 18.00 | 9.00 | 33600 | 2.06 | EPA 3975841 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215681392 | 18.00 | 9.00 | 33400 | 2.06 | EPA 3975855 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →