T5H0V36*K*AAA*
SmartSense 20 VS HP · source records, page 8
300 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for T5H0V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 300 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19.5 | 300 / 300 |
| EER2 · BTU/Wh | 9–11.5 | 300 / 300 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 300 / 300 |
| Cooling capacity · BTU/h | 32,600–35,400 | 300 / 300 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 300 / 300 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–31,400 | 300 / 300 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,400–26,000 | 300 / 300 |
| COP at 5°F / −15°C | 1.75–2.04 | 300 / 300 |
| Equipment / loop type | HP - Split System | 300 / 300 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 300 / 300 |
| Compressor staging | Continuously variable | 300 / 300 |
| Connected capability | No | 300 / 300 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X37M17A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 215668619 | 17.50 | 9.00 | 25600 | 1.86 | EPA 3718145 → |
EA*5X43M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215669035 | 17.50 | 9.00 | 25200 | 1.88 | EPA 3718152 → |
EA*5X37M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215668715 | 17.50 | 9.00 | 25200 | 1.90 | EPA 3718203 → |
EA*5X43M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215669027 | 17.50 | 9.00 | 25200 | 1.88 | EPA 3718207 → |
EA*5X37M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215668739 | 17.50 | 9.00 | 25400 | 1.88 | EPA 3718210 → |
EA*5X37M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215668651 | 17.50 | 9.00 | 25200 | 1.90 | EPA 3718212 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215669121 | 17.50 | 9.00 | 25200 | 1.88 | EPA 3718217 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 215669131 | 17.50 | 9.00 | 25400 | 1.88 | EPA 3718220 → |
EA*5X42M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215668915 | 17.50 | 9.00 | 25600 | 1.86 | EPA 3718246 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 215679522 | 17.50 | 9.00 | 25400 | 1.88 | EPA 3718255 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 215669221 | 17.50 | 9.00 | 25400 | 1.88 | EPA 3718284 → |
EA*5X37M17A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215668579 | 17.50 | 9.00 | 25400 | 1.88 | EPA 3718295 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215669231 | 17.50 | 9.00 | 25200 | 1.90 | EPA 3718299 → |
EA*5X48M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 215669271 | 17.50 | 9.00 | 25400 | 1.88 | EPA 3718300 → |
EA*5X61M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215669511 | 17.50 | 9.00 | 25000 | 1.90 | EPA 3718301 → |
EA*5X37M17A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215668547 | 17.50 | 9.00 | 25600 | 1.88 | EPA 3718314 → |
EA*5X37M17A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 215679272 | 17.50 | 9.00 | 25600 | 1.86 | EPA 3718326 → |
EA*5X42M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215679412 | 17.50 | 9.00 | 25600 | 1.84 | EPA 3718327 → |
EA*5X42M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215679362 | 17.50 | 8.50 | 25600 | 1.86 | EPA 3718336 → |
EA*5X42M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215668923 | 17.50 | 9.00 | 25600 | 1.84 | EPA 3718362 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.