Tempstar / AIR-SOURCE HEAT PUMP

T5H0V24*K*AAA*

SmartSense 20 VS HP · source records, page 3

104 published source records · source checked Sep 21, 2026

SEER2 range15.5–18BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity22,400–24,200BTU/h

Each efficiency range summarizes published EPA records for T5H0V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 104 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–18104 / 104
EER2 · BTU/Wh9–10.5104 / 104
HSPF2 · BTU/Wh8.5–9104 / 104
Cooling capacity · BTU/h22,400–24,200104 / 104
Heating capacity at 47°F / 8.3°C · BTU/h23,200–24,600104 / 104
Heating capacity at 17°F / −8.3°C · BTU/h19,600–20,800104 / 104
Heating capacity at 5°F / −15°C · BTU/h16,300–17,300104 / 104
COP at 5°F / −15°C1.82–2.02104 / 104
Equipment / loop typeHP - Split System104 / 104
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)104 / 104
Compressor stagingContinuously variable104 / 104
Connected capabilityNo104 / 104

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X30M14A*+WALLCON+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 21566734217.008.50167001.86EPA 3800035
EA*5X37M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21566789917.009.00164002.02EPA 3800057
EA*5X24M17A*+WALLCON+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 21566703417.009.00168001.96EPA 3800078
EA*5X25M17A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21567823217.009.00163002.02EPA 3800173
EA*5X24M17A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21566706917.009.00168001.96EPA 3800178
EA*5X25M17A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 21566717717.009.00165002.00EPA 3800206
EA*5X30M17A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21566746417.009.00167001.98EPA 3800216
EA*5X36M17A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21566771517.009.00167001.96EPA 3800230
EA*5X36M17A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 21566772317.009.00166001.98EPA 3800240
EA*5X36M17A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21566769517.009.00167001.98EPA 3800248
EA*5X30M17A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 21566755817.009.00167001.98EPA 3801268
EA*5X36M17A*+WALLCON+ furnace: *80CSU0401712A*Cold climate designationAHRI reference: 21566757517.009.00166001.98EPA 3801277
EA*5X37M17A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 21566774717.009.00166001.98EPA 3801289
EA*5X25M17A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 21567826217.009.00165002.02EPA 3801305
EA*5X37M17A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 21566781117.009.00165002.00EPA 3801337
EA*5X25M17A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21566730417.009.00165002.02EPA 3801349
EA*5X36M17A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 21566767717.009.00167001.98EPA 3801373
EA*5X37M17A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 21567838217.009.00165002.00EPA 3801383
EA*5X36M17A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 21567834217.009.00167001.98EPA 3801406
EA*5X37M17A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 21566777917.009.00166001.98EPA 3801446

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →