R5H5S31*K*AAA*
15 SEER2 HP
39 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for R5H5S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 39 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 39 / 39 |
| EER2 · BTU/Wh | 11.7–13 | 39 / 39 |
| HSPF2 · BTU/Wh | 7.8–8 | 39 / 39 |
| Cooling capacity · BTU/h | 27,400–29,400 | 39 / 39 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,400–30,600 | 39 / 39 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,500–18,200 | 39 / 39 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–14,000 | 39 / 39 |
| COP at 5°F / −15°C | 2–2.06 | 39 / 39 |
| Equipment / loop type | HP - Split System | 39 / 39 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 39 / 39 |
| Compressor staging | Single stage | 39 / 39 |
| Connected capability | No | 39 / 39 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FHMA5*42L*C*AHRI reference: 217683395 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4506016 → |
F5MA5*42L*C*AHRI reference: 217683396 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4506019 → |
FM(C,U)5Z36**AL*AHRI reference: 217683524 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506135 → |
FM(C,U)5Z30**AL*AHRI reference: 217683492 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506709 → |
FMA5X30**AL*AHRI reference: 217683620 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506725 → |
FMA5X36**AL*AHRI reference: 217683652 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506757 → |
FHMA5*30L*B*AHRI reference: 217683267 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4505667 → |
F5MA5*30L*B*AHRI reference: 217683268 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4505668 → |
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 217692247 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506771 → |
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 217691575 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506793 → |
EA*5X43M21A*+ furnace: *95MSU1002122A*AHRI reference: 217693101 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506812 → |
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 217690843 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506836 → |
EA*5X37M21A*+ furnace: *92MSN1002120A*AHRI reference: 217690868 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506861 → |
EA*5X37M21A*+ furnace: *80CSU0802120B*AHRI reference: 217690017 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506874 → |
EA*5X37M21A*+ furnace: *80CSU0401712B*AHRI reference: 217689973 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4506896 → |
EA*5X37M21A*+ furnace: *92MSN1002122A*AHRI reference: 217690888 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506912 → |
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 217693401 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506930 → |
EA*5X43M21A*+ furnace: *97VTN1002122A*AHRI reference: 217693519 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506964 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 217690183 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506989 → |
EA*5X37M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 217690208 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507014 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →