R5H5S24*K*AAA*
15 SEER2 HP · source records, page 2
187 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for R5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 187 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 187 / 187 |
| EER2 · BTU/Wh | 11.7–13 | 187 / 187 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 187 / 187 |
| Cooling capacity · BTU/h | 22,200–24,400 | 187 / 187 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,600–24,000 | 187 / 187 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 187 / 187 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,800–11,900 | 187 / 187 |
| COP at 5°F / −15°C | 1.96–2.26 | 187 / 187 |
| Equipment / loop type | HP - Split System | 187 / 187 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 187 / 187 |
| Compressor staging | Single stage | 187 / 187 |
| Connected capability | No | 187 / 187 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X38M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 214213993 | 16.00 | 7.80 | 11400 | 2.00 | EPA 3410863 → |
EA*5X25M17A*+ furnace: *80CTL0701412B*AHRI reference: 214210638 | 16.00 | 7.80 | 11400 | 2.12 | EPA 3410914 → |
EVD5X38M17A*+ furnace: *80VSL0901716B*AHRI reference: 214214159 | 16.00 | 7.80 | 11400 | 2.00 | EPA 3410948 → |
EA*5X37M21A*+ furnace: *95CSU1002122B*AHRI reference: 214211561 | 16.00 | 7.80 | 11600 | 2.14 | EPA 3411064 → |
EA*5X37M21A*+ furnace: *97CMN1002122A*AHRI reference: 214211588 | 16.00 | 7.80 | 11200 | 2.12 | EPA 3411092 → |
EVD5X38M17A*+ furnace: *80MSU0601716A*AHRI reference: 214214253 | 16.00 | 7.80 | 11200 | 2.02 | EPA 3411154 → |
EA*5X37M21A*+ furnace: *97CMN1002122B*AHRI reference: 214211642 | 16.00 | 7.80 | 11500 | 2.14 | EPA 3411227 → |
EA*5X37M21A*+ furnace: *97CMN0802120B*AHRI reference: 214211615 | 16.00 | 7.80 | 11500 | 2.14 | EPA 3411316 → |
EVD5X38M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 214214057 | 16.00 | 7.80 | 11200 | 2.00 | EPA 3411341 → |
EVD5X31M17A*+ furnace: *80MSU0601716A*AHRI reference: 214213294 | 16.00 | 7.80 | 11200 | 2.00 | EPA 3411350 → |
EVD5X38M17A*+ furnace: *80VSL0701716B*AHRI reference: 214214134 | 16.00 | 7.80 | 11300 | 1.98 | EPA 3411362 → |
EVM5X32M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 214212562 | 16.00 | 7.80 | 11200 | 1.98 | EPA 3411882 → |
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 215800299 | 16.00 | 8.00 | 11400 | 2.10 | EPA 3653626 → |
EA*5X37M21A*+ furnace: *97VTN1002120A*AHRI reference: 215800274 | 16.00 | 8.00 | 11500 | 2.10 | EPA 3653654 → |
FM(C,U)5Z30**AL*AHRI reference: 215828956 | 16.00 | 7.80 | 11100 | 1.98 | EPA 3713370 → |
FM(C,U)5Z36**AL*AHRI reference: 215828988 | 16.00 | 7.80 | 11100 | 1.98 | EPA 3713402 → |
FHMA5*36L*B*AHRI reference: 214179794 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3404583 → |
FTMA5X24L0B*AHRI reference: 214179878 | 15.50 | 7.80 | 11200 | 2.08 | EPA 3404648 → |
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 214197589 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405457 → |
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 214197616 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405484 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →