Tempstar / AIR-SOURCE HEAT PUMP

Q5H9V60*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 3

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for Q5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M21A*+ furnace: *97CTN1002122A*AHRI reference: 21792127216.008.00405001.96EPA 4540830
EVD5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 21792101716.008.00405001.96EPA 4541079
EVD5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 21792103216.008.00405001.96EPA 4541092
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21792014416.008.00395001.96EPA 4541129
EVM5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21791850316.008.00390001.94EPA 4541154
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21791851816.008.00390001.94EPA 4541167
EVM5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21791853316.008.00395001.94EPA 4541182
EVM5X60M21A*+ furnace: *96CTN1002122B*AHRI reference: 21791883316.008.00395001.94EPA 4541199
EVM5X60M21A*+ furnace: *97CTN1002122A*AHRI reference: 21791886316.008.00395001.94EPA 4541230
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21793251216.009.00405002.12EPA 4541972
EA*5X61M24A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 21793254216.008.50410002.00EPA 4542002
EA*5X61M24A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21793255716.008.50410002.00EPA 4542185
EA*5X61M24A*+ furnace: OLV154F20ACold climate designationAHRI reference: 21793300816.009.00410002.14EPA 4542407
EA*5X61M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21793228716.008.50410002.00EPA 4542808
EA*5X61M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21793203216.008.50410002.05EPA 4543220
EA*5X60M24A*+ furnace: *97VTN1002122A*AHRI reference: 21793197216.009.00400002.14EPA 4543259
EA*5X61M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 21793204716.009.00410002.14EPA 4543275
EA*5X61M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21793207716.008.50410002.00EPA 4543417
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21793209216.008.50405002.00EPA 4543435
EA*5X60M24A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21793186716.009.00405002.12EPA 4543481

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.