Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 25
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M21A*+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 217952873 | 15.20 | 9.00 | 37600 | 2.08 | EPA 4558977 → |
EA*5X61M21A*+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 217952901 | 15.20 | 9.00 | 37600 | 2.08 | EPA 4559218 → |
ESH5X48M12A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217953083 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4560417 → |
ESH5X48M12A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217953097 | 15.20 | 8.50 | 37000 | 2.00 | EPA 4560432 → |
ESH5X48M12A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 217953111 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4560469 → |
ESH5X48M12A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217953125 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4560483 → |
ESH5X48M12A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217953027 | 15.20 | 8.50 | 37000 | 2.00 | EPA 4561642 → |
ESH5X48M12A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217953041 | 15.20 | 8.50 | 37000 | 1.98 | EPA 4561656 → |
ESH5X48M12A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217953055 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4561710 → |
ESH5X48M12A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217953069 | 15.20 | 8.50 | 37000 | 2.00 | EPA 4561723 → |
ESH5X60M12A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217953252 | 15.20 | 8.50 | 37000 | 2.00 | EPA 4561807 → |
ESH5X60M12A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217953266 | 15.20 | 8.50 | 37200 | 1.95 | EPA 4561821 → |
ESH5X60M12A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217953280 | 15.20 | 9.00 | 37000 | 2.08 | EPA 4561836 → |
ESH5X60M12A*+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 217953294 | 15.20 | 8.50 | 37200 | 1.95 | EPA 4561849 → |
EVD5X60M24A*+TDRCold climate designationAHRI reference: 217954602 | 15.20 | 9.00 | 39500 | 2.10 | EPA 4562117 → |
EA*5X48M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217952690 | 15.20 | 9.00 | 37400 | 2.10 | EPA 4562828 → |
EVM5X60M21A*+TDRCold climate designationAHRI reference: 217954504 | 15.20 | 9.00 | 39500 | 2.10 | EPA 4563518 → |
EVM5X60M24A*+TDRCold climate designationAHRI reference: 217954518 | 15.20 | 9.00 | 39500 | 2.10 | EPA 4563530 → |
EVD5X48M21A*+TDRCold climate designationAHRI reference: 217954546 | 15.20 | 9.00 | 39000 | 2.10 | EPA 4563547 → |
EVD5X60M21A*+TDRCold climate designationAHRI reference: 217954588 | 15.20 | 9.00 | 39500 | 2.10 | EPA 4563569 → |