Q5H9V36*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 8
450 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X37M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217912243 | 15.50 | 8.50 | 26200 | 2.00 | EPA 4533610 → |
EVD5X48M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217914119 | 15.50 | 8.50 | 26200 | 2.00 | EPA 4534149 → |
FTMA5B36L0C*Cold climate designationAHRI reference: 217908887 | 15.50 | 9.00 | 25400 | 2.08 | EPA 4534359 → |
EVM5X36M17A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217908902 | 15.50 | 8.50 | 25800 | 2.00 | EPA 4534373 → |
EVM5X36M17A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217908917 | 15.50 | 8.50 | 25600 | 2.05 | EPA 4534388 → |
EVM5X36M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217909204 | 15.50 | 8.50 | 26000 | 2.02 | EPA 4534394 → |
EVM5X48M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217910352 | 15.50 | 8.50 | 26200 | 2.00 | EPA 4534482 → |
EVD5X42M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217913378 | 15.50 | 8.50 | 26000 | 2.02 | EPA 4534806 → |
EVD5X42M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217913983 | 15.50 | 8.50 | 26400 | 2.00 | EPA 4535030 → |
EVD5X42M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217913440 | 15.50 | 8.50 | 26200 | 2.00 | EPA 4535252 → |
EVD5X36M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217911653 | 15.50 | 8.50 | 26200 | 2.00 | EPA 4535661 → |
EVD5X36M17A*+ furnace: *80CSU0401712B*AHRI reference: 217911109 | 15.50 | 7.80 | 25800 | 2.05 | EPA 4535783 → |
EVD5X36M17A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217911124 | 15.50 | 8.50 | 25600 | 2.05 | EPA 4535798 → |
EVD5X36M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217911139 | 15.50 | 8.50 | 25800 | 2.02 | EPA 4535813 → |
EVD5X36M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217911154 | 15.50 | 8.50 | 25800 | 2.02 | EPA 4535860 → |
EVD5X48M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217914510 | 15.50 | 8.50 | 26400 | 2.00 | EPA 4536211 → |
EA*5X48M21A*+ furnace: *80MSU0401712A*AHRI reference: 217925536 | 15.50 | 9.00 | 25200 | 2.06 | EPA 4536319 → |
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 217925551 | 15.50 | 9.00 | 25200 | 2.06 | EPA 4536333 → |
EA*5X42M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217924049 | 15.50 | 9.00 | 25400 | 2.10 | EPA 4536426 → |
EA*5X42M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217923959 | 15.50 | 9.00 | 25400 | 2.08 | EPA 4536475 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →