Q5H9V36*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 19
450 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X42M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217913455 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4535272 → |
EVD5X38M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217913015 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4535565 → |
EVM5X36M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217909114 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535610 → |
EVM5X36M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217909144 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535628 → |
EVD5X42M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217913816 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535644 → |
EVD5X38M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217913046 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4535701 → |
EVM5X48M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217910668 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4535834 → |
EVM5X48M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217910683 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4535858 → |
EVD5X36M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217911473 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535931 → |
EVD5X42M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217913241 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535946 → |
EVD5X42M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217913257 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535962 → |
EVD5X42M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217913273 | 15.20 | 8.50 | 26000 | 2.00 | EPA 4535978 → |
EVD5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217912667 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4535984 → |
EVD5X42M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217913288 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4536048 → |
EVD5X36M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217911351 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4536067 → |
EVD5X36M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217911381 | 15.20 | 8.50 | 26000 | 2.00 | EPA 4536085 → |
EVD5X48M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217914480 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4536196 → |
EA*5X42M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217924034 | 15.20 | 9.00 | 25600 | 2.08 | EPA 4536411 → |
EA*5X42M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217923974 | 15.20 | 8.50 | 25600 | 1.95 | EPA 4536491 → |
EA*5X43M21A*+ furnace: *95MSU0802120A*AHRI reference: 217925086 | 15.20 | 9.00 | 24800 | 2.08 | EPA 4536562 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →