Tempstar / AIR-SOURCE HEAT PUMP

Q5H9V36*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 11

450 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for Q5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18450 / 450
EER2 · BTU/Wh10.5–13.5450 / 450
HSPF2 · BTU/Wh7.8–9450 / 450
Cooling capacity · BTU/h33,400–37,600450 / 450
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400450 / 450
Heating capacity at 17°F / −8.3°C · BTU/h25,200–37,600450 / 450
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600450 / 450
COP at 5°F / −15°C1.9–2.18450 / 450
Equipment / loop typeHP - Split System450 / 450
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)450 / 450
Compressor stagingContinuously variable450 / 450
Connected capabilityNo450 / 450

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21792571715.509.00252002.08EPA 4538998
EA*5X37M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21792263615.509.00254002.08EPA 4539217
EA*5X37M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 21792262115.509.00256002.08EPA 4539225
EA*5X43M21A*+ furnace: *96VTN1002120B*AHRI reference: 21792529615.509.00248002.08EPA 4539280
EA*5X42M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21792427515.509.00256002.08EPA 4539343
EA*5X36M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21792222915.508.50250002.00EPA 4539350
EA*5X42M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 21792394415.509.00256002.08EPA 4539528
EA*5X43M21A*+ furnace: *80VSL0701716B*AHRI reference: 21792463515.509.00248002.06EPA 4539550
EA*5X43M21A*+ furnace: *80VSL1102122B*AHRI reference: 21792468015.508.50246001.96EPA 4539569
EA*5X43M21A*+ furnace: *80MSU0401712A*AHRI reference: 21792469515.509.00248002.06EPA 4539589
EA*5X43M21A*+ furnace: *80VSL0901716B*AHRI reference: 21792465015.509.00248002.08EPA 4539626
EA*5X43M21A*+ furnace: *80VSL0902120B*AHRI reference: 21792466515.509.00248002.08EPA 4539641
EA*5X37M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 21792257615.509.00256002.08EPA 4540068
EA*5X37M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 21792259115.509.00256002.08EPA 4540084
EA*5X37M17A*+ furnace: *80VSL0701716B*AHRI reference: 21792260615.509.00256002.08EPA 4540098
EA*5X37M21A*+ furnace: *96VSN0802120B*AHRI reference: 21792347915.509.00248002.08EPA 4540116
EA*5X37M21A*+ furnace: *96VSN1002120B*AHRI reference: 21792349415.509.00248002.06EPA 4540134
EA*5X37M21A*+ furnace: *80CSU0601716B*AHRI reference: 21792302815.509.00246002.04EPA 4540189
EA*5X37M21A*+ furnace: *80CSU0802120B*AHRI reference: 21792304315.509.00246002.06EPA 4540208
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21792329915.509.00248002.08EPA 4540322