Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 35
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X30M17A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 217940786 | 17.50 | 8.50 | 21600 | 1.92 | EPA 4552854 → |
EVD5X24M17A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 217939438 | 17.50 | 8.50 | 21200 | 1.90 | EPA 4553123 → |
EVD5X25M17A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 217940058 | 17.50 | 8.50 | 21600 | 1.92 | EPA 4553302 → |
EVD5X24M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 217939165 | 17.50 | 8.50 | 21000 | 1.88 | EPA 4553650 → |
EVM5X31M17A*+ furnace: *96CTN0401410B*Cold climate designationAHRI reference: 217937333 | 17.50 | 8.50 | 22000 | 1.92 | EPA 4553798 → |
EVM5X31M17A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 217937228 | 17.50 | 8.50 | 22000 | 1.92 | EPA 4553915 → |
EVD5X24M17A*+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 217939285 | 17.50 | 8.50 | 21000 | 1.88 | EPA 4554479 → |
EVD5X24M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217939300 | 17.50 | 8.50 | 20800 | 1.86 | EPA 4554494 → |
EVD5X31M17A*+ furnace: *96VTN0401410B*Cold climate designationAHRI reference: 217941242 | 17.50 | 8.50 | 22200 | 1.92 | EPA 4554566 → |
EVM5X31M17A*+ furnace: *96VTN0401410B*Cold climate designationAHRI reference: 217937409 | 17.50 | 8.50 | 21800 | 1.92 | EPA 4555529 → |
EVD5X25M14A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 217939544 | 17.50 | 8.50 | 21200 | 1.90 | EPA 4555643 → |
EVD5X25M14A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 217939590 | 17.50 | 8.50 | 21200 | 1.90 | EPA 4555690 → |
EVM5X30M17A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 217936653 | 17.50 | 8.50 | 22000 | 1.90 | EPA 4555721 → |
EVM5X30M17A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 217936668 | 17.50 | 8.50 | 21800 | 1.92 | EPA 4555736 → |
EVD5X30M14A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 217940271 | 17.50 | 8.50 | 21400 | 1.90 | EPA 4556169 → |
ESH5X36M12A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217947163 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4558134 → |
EA*5X25M17A*+ furnace: OLV098A12*Cold climate designationAHRI reference: 217951355 | 17.50 | 10.00 | 21200 | 2.00 | EPA 4558398 → |
EA*5X30M17A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217951370 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4558413 → |
EA*5X30M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217951385 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4558429 → |
EA*5X30M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217951400 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4558444 → |