N5H9V60*K*AAA*
Performance 19 SEER2 VS HP · source records, page 4
212 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17.5 | 212 / 212 |
| EER2 · BTU/Wh | 10–12 | 212 / 212 |
| HSPF2 · BTU/Wh | 8–9 | 212 / 212 |
| Cooling capacity · BTU/h | 54,000–57,500 | 212 / 212 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–62,000 | 212 / 212 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 48,000–50,500 | 212 / 212 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–42,000 | 212 / 212 |
| COP at 5°F / −15°C | 1.94–2.16 | 212 / 212 |
| Equipment / loop type | HP - Split System | 212 / 212 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 212 / 212 |
| Compressor staging | Continuously variable | 212 / 212 |
| Connected capability | No | 212 / 212 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X60M24A*+ furnace: *80VSL1352422B*AHRI reference: 217931529 | 16.00 | 9.00 | 40000 | 2.12 | EPA 4543569 → |
EA*5X60M24A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217931514 | 16.00 | 9.00 | 40500 | 2.12 | EPA 4543573 → |
EA*5X61M24A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 217932686 | 16.00 | 8.50 | 41000 | 2.00 | EPA 4543722 → |
EA*5X61M24A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217932716 | 16.00 | 9.00 | 41000 | 2.14 | EPA 4543785 → |
EA*5X61M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217932130 | 16.00 | 9.00 | 41000 | 2.14 | EPA 4543815 → |
EA*5X61M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217932145 | 16.00 | 9.00 | 41000 | 2.14 | EPA 4543830 → |
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 217932160 | 16.00 | 9.00 | 40500 | 2.14 | EPA 4543845 → |
EA*5X61M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217932115 | 16.00 | 8.50 | 41000 | 2.00 | EPA 4543903 → |
EA*5X61M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217932205 | 16.00 | 8.50 | 41000 | 2.00 | EPA 4543909 → |
EA*5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 217932731 | 16.00 | 9.00 | 40500 | 2.14 | EPA 4544193 → |
EA*5X61M24A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217932776 | 16.00 | 8.50 | 41000 | 2.05 | EPA 4544236 → |
EA*5X61M24A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217932806 | 16.00 | 9.00 | 41000 | 2.14 | EPA 4544433 → |
EA*5X61M24A*+ furnace: *96CTN1202422B*AHRI reference: 217932821 | 16.00 | 9.00 | 40500 | 2.14 | EPA 4544448 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217931544 | 16.00 | 8.50 | 40500 | 2.00 | EPA 4544483 → |
EA*5X60M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217931499 | 16.00 | 9.00 | 40500 | 2.12 | EPA 4544499 → |
EA*5X60M24A*+ furnace: *97VTN1002122A*AHRI reference: 217931965 | 16.00 | 9.00 | 40000 | 2.14 | EPA 4544608 → |
EA*5X60M24A*+ furnace: OLV154F20ACold climate designationAHRI reference: 217931995 | 16.00 | 9.00 | 41000 | 2.12 | EPA 4544621 → |
EA*5X61M24A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217932565 | 16.00 | 9.00 | 41000 | 2.14 | EPA 4544775 → |
EA*5X61M24A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217932580 | 16.00 | 9.00 | 41000 | 2.14 | EPA 4544790 → |
EA*5X61M24A*+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 217932595 | 16.00 | 9.00 | 41000 | 2.14 | EPA 4544839 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →