N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 7
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X60M24A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217929138 | 16.50 | 9.00 | 37200 | 2.08 | EPA 4544828 → |
EA*5X61M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217929529 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4544997 → |
EA*5X61M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217929516 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4545035 → |
EA*5X61M24A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217930128 | 16.50 | 9.00 | 37200 | 2.10 | EPA 4545447 → |
EA*5X48M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217928852 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4545465 → |
EA*5X48M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217928865 | 16.50 | 9.00 | 36600 | 2.10 | EPA 4545744 → |
EA*5X48M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217928878 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4545756 → |
EA*5X60M24A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217929347 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4545785 → |
EA*5X48M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217928891 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4545806 → |
EA*5X48M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217928904 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4545817 → |
EA*5X48M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217928917 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4545831 → |
EA*5X48M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217928995 | 16.50 | 9.00 | 36800 | 2.08 | EPA 4546374 → |
EA*5X61M24A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217929880 | 16.50 | 9.00 | 37200 | 2.10 | EPA 4546688 → |
EA*5X61M24A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217929919 | 16.50 | 9.00 | 37200 | 2.10 | EPA 4546727 → |
EA*5X61M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217929698 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4546798 → |
ESH5X60M12A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217930883 | 16.50 | 9.00 | 36600 | 2.10 | EPA 4546847 → |
EA*5X61M24A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217929984 | 16.50 | 9.00 | 37400 | 2.08 | EPA 4546937 → |
EA*5X61M24A*+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 217929997 | 16.50 | 9.00 | 37400 | 2.10 | EPA 4546950 → |
EA*5X61M24A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217930037 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4546992 → |
EA*5X48M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217928943 | 16.50 | 9.00 | 36800 | 2.08 | EPA 4547057 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.