N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 23
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 217952966 | 15.50 | 9.00 | 37600 | 2.08 | EPA 4560343 → |
ESH5X48M12A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217953134 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4560493 → |
EA*5X48M21A*+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 217952600 | 15.50 | 9.00 | 37400 | 2.08 | EPA 4561206 → |
EA*5X48M21A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217952614 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4561220 → |
EA*5X48M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217952700 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4562841 → |
EA*5X48M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217952714 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4562856 → |
EA*5X60M24A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217952742 | 15.50 | 9.00 | 37400 | 2.08 | EPA 4562913 → |
EA*5X60M24A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217952728 | 15.50 | 9.00 | 37600 | 2.08 | EPA 4562924 → |
EA*5X48M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217952558 | 15.50 | 9.00 | 37400 | 2.08 | EPA 4563496 → |
EA*5X48M21A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217952572 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4563509 → |
EVM5X61M24A*+TDRCold climate designationAHRI reference: 217954527 | 15.50 | 9.50 | 40000 | 2.24 | EPA 4563539 → |
EVD5X61M24A*+TDRCold climate designationAHRI reference: 217954625 | 15.50 | 9.50 | 40000 | 2.24 | EPA 4565540 → |
EVM5X48M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217915166 | 15.20 | 9.00 | 40000 | 2.12 | EPA 4530434 → |
EVM5X48M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217915244 | 15.20 | 9.00 | 40500 | 2.10 | EPA 4531346 → |
EVM5X48M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217915310 | 15.20 | 9.00 | 40000 | 2.10 | EPA 4532083 → |
EVM5X48M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217915349 | 15.20 | 9.00 | 40000 | 2.10 | EPA 4532448 → |
EVD5X49M24A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217916744 | 15.20 | 9.00 | 41000 | 2.12 | EPA 4532752 → |
EVM5X48M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217915257 | 15.20 | 9.00 | 40000 | 2.12 | EPA 4535504 → |
EVM5X48M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217915270 | 15.20 | 9.00 | 40500 | 2.10 | EPA 4535516 → |
EVM5X48M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217915283 | 15.20 | 9.00 | 40000 | 2.12 | EPA 4535531 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →