N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 16
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 217930258 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4547139 → |
EA*5X48M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217928930 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4547155 → |
ESH5X60M12A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217931183 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4547182 → |
ESH5X60M12A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217931196 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4547198 → |
EA*5X60M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217929386 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4547472 → |
EA*5X60M24A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 217929412 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4547497 → |
EA*5X60M24A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217952756 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4557175 → |
EA*5X60M24A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217952770 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4557189 → |
EA*5X60M24A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217952784 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4557474 → |
EA*5X60M24A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217952798 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4557488 → |
EA*5X60M24A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217952812 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4558670 → |
EA*5X60M24A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217952826 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4558684 → |
EA*5X60M24A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217952840 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4558698 → |
EA*5X60M24A*+ furnace: OMV154L20ACold climate designationAHRI reference: 217952854 | 16.00 | 9.00 | 37600 | 2.10 | EPA 4558712 → |
EA*5X61M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217952882 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4559199 → |
EA*5X61M24A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217952952 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4560329 → |
EA*5X48M21A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217952586 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4561192 → |
EVD5X61M21A*+TDRCold climate designationAHRI reference: 217954611 | 16.00 | 9.50 | 40000 | 2.24 | EPA 4562126 → |
EA*5X48M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217952544 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4563482 → |
EA*5X61M24A*+ furnace: OMV154L20ACold climate designationAHRI reference: 217952994 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4563647 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →