N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 14
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217930063 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4544167 → |
ESH5X60M12A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217931027 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4544357 → |
EA*5X60M24A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217929243 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4544398 → |
EA*5X61M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217929841 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4544555 → |
EA*5X48M21A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 217928605 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4544647 → |
EA*5X60M24A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217929112 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4544802 → |
EA*5X60M24A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217929125 | 16.00 | 9.00 | 37000 | 2.08 | EPA 4544815 → |
ESH5X60M12A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217931339 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4544922 → |
EA*5X61M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217929490 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4544964 → |
EA*5X60M24A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 217929256 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4545213 → |
EA*5X60M24A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217929282 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4545226 → |
EA*5X61M24A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 217930102 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4545421 → |
EA*5X61M24A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217930115 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4545434 → |
EA*5X61M24A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217930141 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4545458 → |
EA*5X48M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217928813 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4545574 → |
EA*5X48M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217928826 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4545587 → |
EA*5X48M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 217928839 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4545600 → |
ESH5X60M12A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217931053 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4545629 → |
ESH5X60M12A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217931066 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4545642 → |
ESH5X60M12A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 217931079 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4545661 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.