| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X24M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217939355 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4552432 → |
EVD5X24M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217939371 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4552447 → |
EVM5X24M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217935631 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4552459 → |
EVD5X24M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217939051 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4552631 → |
EVD5X24M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217939446 | 18.00 | 8.50 | 21200 | 1.88 | EPA 4552638 → |
EVD5X25M14A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 217939461 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4552652 → |
EVD5X25M17A*+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 217940005 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4552753 → |
EVD5X24M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217939083 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4552784 → |
EVD5X30M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 217940794 | 18.00 | 8.50 | 21600 | 1.88 | EPA 4552862 → |
EVD5X30M17A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 217940886 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4552941 → |
EVM5X30M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217936616 | 18.00 | 8.50 | 21400 | 1.90 | EPA 4552985 → |
EVD5X30M17A*+ furnace: OLV098A12*Cold climate designationAHRI reference: 217940871 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4553209 → |
EVD5X31M17A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 217941098 | 18.00 | 8.50 | 22200 | 1.92 | EPA 4553277 → |
EVD5X25M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 217940066 | 18.00 | 8.50 | 21600 | 1.88 | EPA 4553309 → |
EVD5X24M14A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 217938734 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4553702 → |
EVD5X24M14A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217938749 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4553720 → |
EVD5X36M17A*+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 217941461 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4553835 → |
EVD5X24M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 217939173 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4553845 → |
EVD5X24M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217939188 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4553859 → |
EVD5X24M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 217939203 | 18.00 | 8.10 | 21200 | 1.80 | EPA 4553874 → |