N5H9V24*K*AAA*
Performance 19 SEER2 VS HP · source records, page 26
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X24M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217939098 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4547942 → |
EVD5X24M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217939113 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4547956 → |
EVD5X24M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217939401 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4548181 → |
EVD5X24M14A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 217938764 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4548553 → |
EVD5X24M14A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217938779 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4548568 → |
EVM5X30M17A*+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 217936524 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4548739 → |
EVM5X30M17A*+ furnace: OLV098A12*Cold climate designationAHRI reference: 217936919 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4549154 → |
EVM5X30M17A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 217936934 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4549175 → |
EVD5X36M21A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 217942314 | 18.00 | 8.50 | 21400 | 1.88 | EPA 4549224 → |
EVM5X36M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 217938431 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4549313 → |
EVM5X36M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 217938476 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4549358 → |
EVM5X24M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217935404 | 18.00 | 8.50 | 21200 | 1.88 | EPA 4549434 → |
EVM5X24M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217935435 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4549443 → |
EVM5X24M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217935419 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4549449 → |
EVM5X24M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217935451 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4549530 → |
EVM5X25M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 217936297 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4549708 → |
EVM5X24M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217935739 | 18.00 | 8.50 | 21200 | 1.88 | EPA 4549808 → |
EVM5X24M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217935754 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4549823 → |
EVM5X24M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217935769 | 18.00 | 8.50 | 21200 | 1.88 | EPA 4549838 → |
EVD5X31M17A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 217941113 | 18.00 | 8.50 | 22000 | 1.92 | EPA 4549958 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →