N5H9V24*K*AAA*
Performance 19 SEER2 VS HP · source records, page 22
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X25M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 217939900 | 18.50 | 8.50 | 21600 | 1.90 | EPA 4555779 → |
EVM5X30M17A*+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 217936781 | 18.50 | 8.50 | 21800 | 1.90 | EPA 4556002 → |
EVD5X30M14A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 217940218 | 18.50 | 8.50 | 21400 | 1.88 | EPA 4556023 → |
EVD5X30M14A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217940233 | 18.50 | 8.50 | 21200 | 1.88 | EPA 4556131 → |
EVM5X31M17A*+ furnace: OLV098A12*Cold climate designationAHRI reference: 217937509 | 18.50 | 8.50 | 21800 | 1.92 | EPA 4556521 → |
EVM5X31M17A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 217937524 | 18.50 | 8.50 | 21800 | 1.92 | EPA 4556537 → |
EVD5X24M17A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 217939006 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4556563 → |
EVD5X24M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217939021 | 18.50 | 8.50 | 21200 | 1.86 | EPA 4556577 → |
EA*5X25M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217946554 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4556619 → |
EA*5X25M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 217946569 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4556634 → |
EA*5X25M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217946599 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4556650 → |
EA*5X37M21A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217950426 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4556731 → |
EA*5X37M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217950442 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4556746 → |
EA*5X37M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217947441 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4557095 → |
EA*5X37M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217947456 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4557108 → |
EA*5X37M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217950683 | 18.50 | 10.00 | 21200 | 1.95 | EPA 4557317 → |
EA*5X37M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217950698 | 18.50 | 10.00 | 21000 | 1.95 | EPA 4557332 → |
EA*5X37M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217947471 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4557830 → |
EA*5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217947486 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4557842 → |
EA*5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217947501 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4557906 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →