Tempstar / AIR-SOURCE HEAT PUMP

N5H8T60*K*AAA*

2-STAGE 18 SEER HP · source records, page 4

122 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5122 / 122
EER2 · BTU/Wh11.7–13122 / 122
HSPF2 · BTU/Wh7.8–8.5122 / 122
Cooling capacity · BTU/h54,000–58,000122 / 122
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500122 / 122
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500122 / 122
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800122 / 122
COP at 5°F / −15°C2.1–2.34122 / 122
Equipment / loop typeHP - Split System122 / 122
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)122 / 122
Compressor stagingTwo-stage122 / 122
Connected capabilityNo122 / 122

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21562816616.008.50318002.32EPA 3950740
EVD5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21562818316.008.50316002.34EPA 3950757
EA*5X60M24A*+ furnace: *80VTL0902120B*AHRI reference: 21562919416.008.00298002.25EPA 3950893
EA*5X60M24A*+ furnace: *80VTL1102122B*AHRI reference: 21562921016.008.00298002.30EPA 3950911
EA*5X60M24A*+ furnace: *95CSU1002122B*AHRI reference: 21562924816.008.00296002.30EPA 3950933
EA*5X60M24A*+ furnace: *97CMN0802120B*AHRI reference: 21562927616.008.00300002.25EPA 3950949
EA*5X60M24A*+ furnace: *80VSL0902120B*AHRI reference: 21562905816.008.00298002.25EPA 3950971
EA*5X60M24A*+ furnace: *80VSL1102122B*AHRI reference: 21562907116.008.00298002.30EPA 3950986
EA*5X60M24A*+ furnace: *80VSL1352422B*AHRI reference: 21562908416.008.00296002.25EPA 3950998
EA*5X60M24A*+ furnace: *80MSU1002120A*AHRI reference: 21562912016.008.00296002.30EPA 3951034
EA*5X60M24A*+ furnace: *80CTL0902120B*AHRI reference: 21562915016.008.00300002.30EPA 3951049
EA*5X60M24A*+ furnace: *80CTL1102120B*AHRI reference: 21562916416.008.00300002.25EPA 3951065
EA*5X60M24A*+ furnace: *80CTL1352422B*AHRI reference: 21562917816.008.00300002.30EPA 3951078
EA*5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21562982916.008.00302002.25EPA 3951096
EA*5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21562986516.008.00302002.25EPA 3951113
EA*5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562988416.008.00302002.30EPA 3951129
EA*5X60M24A*+ furnace: *97CMN1002122B*AHRI reference: 21562929016.008.00300002.25EPA 3951171
EA*5X60M24A*+ furnace: *96VSN0802120B*AHRI reference: 21562931716.008.00300002.25EPA 3951185
EA*5X60M24A*+ furnace: *96VSN1002120B*AHRI reference: 21562933016.008.00298002.25EPA 3951203
EA*5X60M24A*+ furnace: *96VSN1202422B*AHRI reference: 21562934316.008.00298002.25EPA 3951223

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →