N5H8T60*K*AAA*
2-STAGE 18 SEER HP
122 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–17.5 | 122 / 122 |
| EER2 · BTU/Wh | 11.7–13 | 122 / 122 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 122 / 122 |
| Cooling capacity · BTU/h | 54,000–58,000 | 122 / 122 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–61,500 | 122 / 122 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 36,200–38,500 | 122 / 122 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,600–31,800 | 122 / 122 |
| COP at 5°F / −15°C | 2.1–2.34 | 122 / 122 |
| Equipment / loop type | HP - Split System | 122 / 122 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 122 / 122 |
| Compressor staging | Two-stage | 122 / 122 |
| Connected capability | No | 122 / 122 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B60L0D*AHRI reference: 215560753 | 17.50 | 8.10 | 30200 | 2.30 | EPA 3982836 → |
QFVA5D6021X*AHRI reference: 218695470 | 17.50 | 8.10 | 31400 | 2.34 | EPA 4683357 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 215629101 | 16.50 | 8.00 | 29600 | 2.30 | EPA 3951015 → |
EA*5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 215629900 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951146 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 215629977 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951230 → |
EA*5X61M24A*+ furnace: *80CSU0802120A*AHRI reference: 215629991 | 16.50 | 7.80 | 31400 | 2.22 | EPA 3951278 → |
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 215630031 | 16.50 | 8.10 | 29800 | 2.14 | EPA 3951392 → |
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 215630044 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951406 → |
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 215630061 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951426 → |
EA*5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 215630080 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951440 → |
EA*5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 215629586 | 16.50 | 8.10 | 30000 | 2.12 | EPA 3951538 → |
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 215629622 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951576 → |
EA*5X61M24A*+ furnace: *80CTL0902120B*AHRI reference: 215630110 | 16.50 | 8.10 | 30200 | 2.26 | EPA 3951615 → |
EA*5X61M24A*+ furnace: *80CTL1102120B*AHRI reference: 215630124 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951631 → |
EA*5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 215630138 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951645 → |
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 215630170 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951676 → |
EA*5X61M24A*+ furnace: *95CSU1002122B*AHRI reference: 215630208 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951715 → |
EA*5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 215629699 | 16.50 | 8.00 | 30400 | 2.25 | EPA 3951767 → |
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 215629731 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951802 → |
EA*5X61M24A*+ furnace: *97CMN1002122B*AHRI reference: 215630250 | 16.50 | 8.10 | 30400 | 2.12 | EPA 3951811 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →