Tempstar / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 5

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 21562515017.008.50248002.14EPA 3949447 →
EVD5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 21562543517.008.50250002.26EPA 3949468 →
EVD5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21562523717.008.10250002.10EPA 3949495 →
EVD5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562518217.008.10246002.14EPA 3949507 →
EVD5X61M21A*+ furnace: *97CMN0802120B*AHRI reference: 21562521017.008.10252002.10EPA 3949528 →
EVD5X61M21A*+ furnace: *97CMN1002122B*AHRI reference: 21562522417.008.10254002.10EPA 3949546 →
EVD5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21562525017.008.10250002.12EPA 3949553 →
EVD5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562528617.008.50248002.12EPA 3949585 →
EVD5X61M21A*+ furnace: *96CTN0802120B*AHRI reference: 21562531617.008.50252002.10EPA 3949615 →
EVD5X61M21A*+ furnace: *96CTN1002122B*AHRI reference: 21562533017.008.10254002.10EPA 3949628 →
EVD5X61M24A*+ furnace: *97CMN1002122B*AHRI reference: 21562556317.008.10252002.12EPA 3949669 →
EVD5X61M24A*+ furnace: *96VSN0802120B*AHRI reference: 21562559017.008.10256002.10EPA 3949695 →
EVD5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 21562534617.008.10250002.10EPA 3949715 →
EVD5X61M21A*+ furnace: *96VTN1002120B*AHRI reference: 21562536417.008.10250002.12EPA 3949737 →
EVD5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21562539217.008.50250002.26EPA 3949761 →
EVD5X61M24A*+ furnace: *80CTL0902120B*AHRI reference: 21562546517.008.50250002.26EPA 3949798 →
EVD5X61M24A*+ furnace: *80VTL0902120B*AHRI reference: 21562549517.008.50250002.26EPA 3949830 →
EVD5X61M24A*+ furnace: *96CTN1002122B*AHRI reference: 21562569617.008.10252002.12EPA 3950022 →
EVD5X61M24A*+ furnace: *96CTN1202422B*AHRI reference: 21562571017.008.10252002.12EPA 3950039 →
EVD5X61M24A*+ furnace: *96VTN0802120B*AHRI reference: 21562572617.008.50256002.10EPA 3950055 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →