N5H8T48*K*AAA*
2-STAGE 18 SEER HP · source records, page 17
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11.7–13.5 | 407 / 407 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 45,500–50,500 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 407 / 407 |
| COP at 5°F / −15°C | 2.06–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X60M12A*+ furnace: *80VSL1102122B*AHRI reference: 215634074 | 16.00 | 8.00 | 25000 | 2.25 | EPA 3953994 → |
ESH5X60M12A*+ furnace: *80VSL1352422B*AHRI reference: 215634087 | 16.00 | 8.00 | 25000 | 2.25 | EPA 3954005 → |
ESH5X60M12A*+ furnace: *80MSU0601716A*AHRI reference: 215634104 | 16.00 | 7.80 | 25200 | 2.20 | EPA 3954025 → |
ESH5X60M12A*+ furnace: *96VTN0802120B*AHRI reference: 215634632 | 16.00 | 8.00 | 25200 | 2.20 | EPA 3954038 → |
ESH5X60M12A*+ furnace: *96VTN1002120B*AHRI reference: 215634650 | 16.00 | 8.00 | 25200 | 2.25 | EPA 3954053 → |
ESH5X60M12A*+ furnace: *96VTN1002122B*AHRI reference: 215634665 | 16.00 | 8.00 | 25000 | 2.25 | EPA 3954069 → |
ESH5X60M12A*+ furnace: *96VTN1202422B*AHRI reference: 215634683 | 16.00 | 8.00 | 25200 | 2.25 | EPA 3954090 → |
ESH5X60M12A*+ furnace: *80MSU0802120A*AHRI reference: 215634123 | 16.00 | 8.00 | 24800 | 2.25 | EPA 3954113 → |
ESH5X60M12A*+ furnace: *80CTL0702120B*AHRI reference: 215634186 | 16.00 | 8.00 | 25400 | 2.20 | EPA 3954145 → |
ESH5X60M12A*+ furnace: *80CTL0902120B*AHRI reference: 215634200 | 16.00 | 8.00 | 25200 | 2.25 | EPA 3954162 → |
ESH5X60M12A*+ furnace: *80CTL1102120B*AHRI reference: 215634214 | 16.00 | 8.00 | 25200 | 2.25 | EPA 3954177 → |
ESH5X60M12A*+ furnace: *80CTL1352422B*AHRI reference: 215634228 | 16.00 | 8.00 | 25000 | 2.25 | EPA 3954191 → |
ESH5X60M12A*+ furnace: *80VTL0902120B*AHRI reference: 215634260 | 16.00 | 8.00 | 25000 | 2.25 | EPA 3954206 → |
ESH5X60M12A*+ furnace: *80VTL1102122B*AHRI reference: 215634276 | 16.00 | 8.00 | 25000 | 2.25 | EPA 3954225 → |
ESH5X60M12A*+ furnace: *97CMN1202422B*AHRI reference: 215634398 | 16.00 | 8.00 | 25400 | 2.20 | EPA 3954258 → |
ESH5X60M12A*+ furnace: *96VSN0802120B*AHRI reference: 215634437 | 16.00 | 8.00 | 25200 | 2.20 | EPA 3954274 → |
ESH5X60M12A*+ furnace: *96VSN1002120B*AHRI reference: 215634450 | 16.00 | 8.00 | 25200 | 2.20 | EPA 3954288 → |
ESH5X60M12A*+ furnace: *96VSN1202422B*AHRI reference: 215634463 | 16.00 | 8.00 | 25200 | 2.25 | EPA 3954303 → |
EA*5X60M24A*+ furnace: *97VTN1002122A*AHRI reference: 215721768 | 16.00 | 8.00 | 25400 | 2.22 | EPA 3981814 → |
EA*5X61M21A*+ furnace: *80CSU0802120B*AHRI reference: 215721782 | 16.00 | 8.00 | 25200 | 2.26 | EPA 3981828 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →